NET1 AC-DC Series Data Sheet
MCD10011 Rev. 1.1, 9-Apr-10
Page 3 of 4
www.power-one.com
Safety, Regulatory, and EMI Specifications
PARAMETER
Agency Approvals
CONDITIONS/DESCRIPTION
UL60950.
CSA 22.2 NO. 60950-00 (cUL).
EN60950 (TüV).
Input to output per EN60950.
FCC CFR title 47 Part 15 Sub-Part B - Conducted.
EN55022 / CISPR 22 Conducted.
Per EN61000-4-2, level 4.
Per EN61000-4-3, level 3.
Per EN61000-4-4, level 3.
Per EN61000-4-5, class 3.
MIN
TYP
MAX
UNITS
Approved
Dielectric Withstand Voltage
Electromagnetic Interference
2600
B
B
8
10
±2
1
2
VDC
Class
ESD Susceptibility
Radiated Susceptibility
EFT/Burst
Input Transient Protection
kV
V/M
kV
Line to Line
Line to Ground
kV
Insulation Resistance
Input to output.
10
M
Environmental Specifications
PARAMETER
Altitude
CONDITIONS/DESCRIPTION
Operating.
Non-Operating.
MIN
TYP
MAX
10k
40k
50
85
±0.05
95
20
6
UNITS
ASL Ft.
ASL Ft.
°C
°C
%/°C
%RH
G
PK
G
RMS
Operating Temperature
Storage Temperature
Temperature Coefficient
Relative Humidity
Shock
Vibration
At 100% load
0
-40
0 °C to 70 °C (after 15-minute warmup).
Non-Condensing.
Peak acceleration.
Random vibration, 10 Hz to 2 kHz, 3 axis.
±0.02
5
Mechanical
DESCRIPTION
Metric Mounting
Size
NOTES
M4 x 0.7 mounting inserts: 2 mounting surfaces
SIZE IMPACT
7.00" x 4.50" x 1.35"
(177.8mm x 114.3mm x 34.3mm)
NUCLEAR AND MEDICALAPPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components
in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective
divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.