3
www.fairchildsemi.com
NC7SZ27
AC Electrical Characteristics
Note 3: CPD is defined as the value of the internal equivalent capacitance which is derived from dynamic operating current consumption (ICCD) at no output
loading and operating at 50% duty cycle. (See Figure 2.) CPD is related to ICCD dynamic operating current by the expression:
ICCD = (CPD)(VCC)(fIN) + (ICCstatic).
AC Loading and Waveforms
CL includes load and stray capacitance
Input PRR
= 1.0 MHz; t
w = 500 ns
FIGURE 1. AC Test Circuit
Input
= AC Waveform; t
r = tf = 1.8 ns;
PRR
= 10 MHz; Duty Cycle = 50%
FIGURE 2. ICCD Test Circuit
FIGURE 3. AC Waveforms
Symbol
Parameter
VCC
TA = +25°CTA = 40°C to +85°C
Units
Conditions
Figure
(V)
Min
Typ
Max
Min
Max
Number
tPLH,
Propagation Delay
1.8
± 0.15
2.0
10.0
18.5
2.0
19.0
ns
Figures
1, 3
tPHL
2.5
± 0.2
0.8
5.0
10.5
0.8
11.0
CL = 15 pF,
3.3
± 0.3
0.5
3.2
8.0
0.5
8.5
RL = 1 M
5.0
± 0.5
0.5
2.6
5.5
0.5
6.0
tPLH,
Propagation Delay
3.3
± 0.3
1.5
3.9
8.0
1.5
8.5
ns
CL = 50 pF,
Figures
1, 3
tPHL
5.0
± 0.5
0.8
2.9
5.5
0.8
6.0
RL = 500
CIN
Input Capacitance
0
4
pF
CPD
Power Dissipation
3.3
23
pF
(Note 3)
Figure 2
Capacitance
5.0
30