NB7L111M
http://onsemi.com
5
Table 5. DC CHARACTERISTICS VCC = 2.375 V 2.625 V and 3.135 V to 3.465 V, VEE = 0 V, TA = 40°C to +85°C (Notes 6 and 7) Symbol
Characteristic
Min
Typ
Max
Unit
ICC
Power Supply Current (Inputs and Outputs Open)
VCC = 2.375 V to 2.625 V
VCC = 3.135 V to 3.465 V
255
270
290
305
325
340
mA
VOH
Output HIGH Voltage (Notes
6 and
7)VCC 40
VCC 20
VCC
mV
VOL
Output LOW Voltage (Notes
6 and
7)VCC = 2.375 V to 2.625 V
VCC = 3.135 V to 3.465 V
VCC 440
VCC 490
VCC 350
VCC 400
VCC – 290
VCC 340
mV
DIFFERENTIAL INPUT DRIVEN SINGLEENDED (See Figures
13 and
15) Vth
Input Threshold Reference Voltage Range (Note
8)1125
VCC – 75
mV
VIH
Singleended Input HIGH Voltage (Note
7)Vth + 75
VCC
mV
VIL
Singleended Input LOW Voltage (Note
7)VEE
VCC – 150
mV
DIFFERENTIAL INPUTS DRIVEN DIFFERENTIALLY (See Figures
14 and
16) VIHD
Differential Input HIGH Voltage
1200
VCC
mV
VILD
Differential Input LOW Voltage
VEE
VCC – 75
mV
VCMR
Input Common Mode Range (Differential Configuration) (Note
9)1163
VCC – 37
mV
VID
Differential Input Voltage (VIHD VILD)
75
2500
mV
IIH
Input HIGH Current
CLK[01]/CLK[01]
(Termination Pins Open)
SEL/SEL
100
150
5
100
150
mA
IIL
Input LOW Current
CLK[01]/CLK[01]
(Termination Pins Open)
SEL/SEL
100
150
5
100
150
mA
RTIN
Internal Input Termination Resistor
45
50
55
W
RTOUT
Internal Output Termination Resistor
45
50
55
W
RTemp
Coef
Internal I/O Termination Resistor Temperature Coefficient
3.75
mW/C
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
6. CML outputs require 50 W receiver termination resistors to VCC for proper operation.
7. Input and output parameters vary 1:1 with VCC.
8. Vth is applied to the complementary input when operating in singleended mode.