![](http://datasheet.mmic.net.cn/220000/MPXV5004G6T1_datasheet_15501673/MPXV5004G6T1_2.png)
2
Sensor Device Data
Freescale Semiconductor
MPXV5004G SERIES
MAXIMUM RATINGS
(NOTE)
Parametrics
Symbol
Value
Unit
Maximum Pressure (P1 > P2)
P
max
16
kPa
Storage Temperature
T
stg
--30 to +100
°
C
Operating Temperature
T
A
0 to +85
°
C
NOTE: Exposure beyond the specified limits may cause permanent damage or degradation to the device.
OPERATING CHARACTERISTICS
(V
S
= 5.0 Vdc, T
A
= 25
°
C unless otherwise noted, P1 > P2. Decoupling circuit shown in Figure 3
required to meet electrical specifications)
Characteristic
Symbol
Min
Typ
Max
Unit
Pressure Range
P
OP
0
—
3.92
400
kPa
mm H
2
O
Supply Voltage
(1)
V
S
4.75
5.0
5.25
Vdc
Supply Current
I
S
—
—
10
mAdc
Span at 306 mm H
2
O (3 kPa)
(2)
Offset
(3)(5)
V
FSS
—
3.0
—
V
V
off
0.75
1.00
1.25
V
Sensitivity
V/P
—
1.0
9.8
—
V/kPa
mV/mm H
2
O
Accuracy
(4)(5)
0 to 100 mm H
2
O
100 to 400 mm H
2
O
(10 to 60
°
C)
(10 to 60
°
C)
—
—
—
±
1.5
±
2.5
%V
FSS
%V
FSS
NOTES:
1. Device is ratiometric within this specified excitation range.
2. Span is defined as the algebraic difference between the output voltage at specified pressure and the output voltage at the minimum rated
pressure.
3. Offset (V
off
) is defined as the output voltage at the minimum rated pressure.
4. Accuracy (error budget) consists of the following:
Linearity:
Output deviation from a straight line relationship with pressure over the specified pressure range.
Temperature Hysteresis: Output deviation at any temperature within the operating temperature range, after the temperature is
cycled to and from the minimum or maximum operating temperature points, with zero differential pressure
applied.
Pressure Hysteresis:
Output deviation at any pressure within the specified range, when this pressure is cycled to and from the
minimum or maximum rated pressure, at 25
°
C.
Offset Stability:
Output deviation, after 1000 temperature cycles,
30 to 100
°
C, and 1.5 million pressure cycles, with
minimum rated pressure applied.
TcSpan:
Output deviation over the temperature range of 10 to 60
°
C, relative to 25
°
C.
TcOffset:
Output deviation with minimum rated pressure applied, over the temperature range of 10 to 60
°
C,
relative to 25
°
C.
Variation from Nominal:
The variation from nominal values, for Offset or Full Scale Span, as a percent of V
FSS
, at 25
°
C.
5. AutoZeroatFactory Installation:Duetothesensitivity of theMPXV5004G, externalmechanical stresses and mountingposition canaffect
the zero pressure output reading. Autozeroing is defined as storingthe zeropressure outputreading andsubtracting this from thedevice’s
output during normal operations. Reference AN1636 for specific information. The specified accuracy assumes a maximum temperature
change of
±
5
°
C between autozero and measurement.