Product Highlights
The MI-IAM is an accessory
product to Vicor’s MI-Series of
DC-DC converters that provides
the EMI/RFI filtering and transient
protection required in military
applications. Designed for use
with all 28V and 270V input
MI-200 or MI-J00 converters, the
MI-IAM can drive any number of
modules with output loads to 200W.
The MI-IAM meets the conducted
emissions specifications of MIL-
STD-461C/D and offers complete
input transient, surge, and spike
protection to the most severe
levels of MIL-STD-1275A and
704A. Reverse polarity protection
and overvoltage lockout provide
additional safeguards against
potentially damaging line
conditions. High power arrays can
be configured using the expansion
port capability of the MI-IAM.
MI-IAM
Military Input Attenuator Modules
TM
"
Inputs:
28Vdc and 270Vdc
"
MIL-STD-461C/D EMI compliance
"
MIL-STD-810 environments
"
MIL-STD-704A & MIL-STD1275A
transients and spikes
"
Reverse polarity protection
"
Output power: Up to 200W from
any combination of MI-200 or
MI-J00 modules
"
Expansion port for additional power
"
Short circuit protected
"
Size: 2.28" x 2.4" x 0.5"
(57,9 x 61,0 x 12,7mm)
Specifications
(At TBP= 25°C, nominal line and 75% load, unless otherwise specified)
PARAMETER
Input Characteristics
28Vdc modules
MIN
TYP
MAX
UNITS
NOTES
Steady state input
18.8
-600
-250
28
50
600
250
100
Vdc
Vdc
Vdc
Vdc
Vdc
Input spike limit
10μS,50
per MIL-STD-704A
100μS,15mJ per MIL-STD-1275A
60mS,0.5
per MIL-STD-1275A
100mS,automatic recovery
Shunt diode: input fuse required
F03A type
Input surge limit
Overvoltage shutdown
Reverse polarity protection
Recommended fuse
Steady state input
50
20
400
800
600
500
Amps
Vdc
Vdc
Vdc
Vdc
Vdc
270Vdc modules
125
270
Input spike limit
10μS,50
100μS,15mJ
100mS,0.5
100mS,automatic recovery
Shunt diode: input fuse required
F03A type
-600
Input surge limit
Overvoltage shutdown 400
Reverse polarity protection
Recommended fuse
No load power dissipation
Inrush current
4
Amps
Watts
% Iin
All models
0.5
110
1.5
125
Steady state,lin10mS
EMC Characteristics; MIL-STD-461C/D
Input power leads Conducted emissions
CE01,CE03,CE07
CE101,CE102
MIL-STD-461C
MIL-STD-461D
MIL-STD-461C
MIL-STD-461D
Conducted susceptibility CS01,CS02,CS06
CS101,CS114,CS116
Output Characteristics
Clamp voltage
28Vdc input
270Vdc input
60
420
250
20
4
Vdc
Vdc
Watts
Amps
Amps
Output power
Overload protection
28Vdc input
Foldback threshold; auto recovery
with latched shutdown after 10mS
270Vdc input
Isolation Characteristics
Input to base
Output to base
Environmental (MIL-STD-810)
Altitude - method 500.2
Humidity - method 507.2
Acceleration - method 513.3
Vibration - method 514.3
Shock - method 516.3
Reliability (MIL-HDBK-217F)
25°C Ground Benign: G.B.
50°C Naval Sheltered: N.S.
65°C Airborne Inhabited Cargo: A.I.C.
Thermal Characteristics
Efficiency
Baseplate to sink
Operating temperature,baseplate
Storage temperature
Mechanical Specifications
Weight
1,500
1,500
Vrms
Vrms
1 min.
1 min.
70,000
86/240
9
20
40
feet
Procedure II
%/hours Procedure 1,cycle 1
g's
Procedure
g's
Procedure 1,category 6
g's
Procedure 1
3,352,133
804,512
653,666
hours
hours
hours
97
0.14
%
°C/Watt
°C
°C
100
125
See product grade specifications
See product grade specifications
3 (85)
ounces (grams)
}
Features
MI-IAM 04/03 1 of 2