![](http://datasheet.mmic.net.cn/ON-Semiconductor/MC74HC4066AFEL_datasheet_98768/MC74HC4066AFEL_3.png)
MC74HC4066A
http://onsemi.com
3
MAXIMUM RATINGS
Symbol
Parameter
Value
Unit
VCC
Positive DC Supply Voltage (Referenced to GND)
– 0.5 to + 14.0
V
VIS
Analog Input Voltage (Referenced to GND)
– 0.5 to VCC + 0.5
V
Vin
Digital Input Voltage (Referenced to GND)
– 0.5 to VCC + 0.5
V
I
DC Current Into or Out of Any Pin
± 25
mA
PD
Power Dissipation in Still Air,
SOIC Package
TSSOP Package
500
450
mW
Tstg
Storage Temperature
– 65 to + 150
°C
TL
Lead Temperature, 1 mm from Case for 10 Seconds
(Plastic DIP, SOIC or TSSOP Package)
260
°C
Stresses exceeding those listed in the Maximum Ratings table may damage the device. If any of
these limits are exceeded, device functionality should not be assumed, damage may occur and
reliability may be affected.
Derating SOIC Package: – 7 mW/°C from 65° to 125°C
TSSOP Package: 6.1 mW/°C from 65° to 125°C
RECOMMENDED OPERATING CONDITIONS
Symbol
Parameter
Min
Max
Unit
VCC
Positive DC Supply Voltage (Referenced to GND)
2.0
12.0
V
VIS
Analog Input Voltage (Referenced to GND)
GND
VCC
V
Vin
Digital Input Voltage (Referenced to GND)
GND
VCC
V
VIO*
Static or Dynamic Voltage Across Switch
1.2
V
TA
Operating Temperature, All Package Types
–55
+ 125
°C
tr, tf
Input Rise and Fall Time, ON/OFF Control
Inputs (Figure 10)
VCC = 2.0 V
VCC = 3.0 V
VCC = 4.5 V
VCC = 9.0 V
VCC = 12.0 V
0
1000
600
500
400
250
ns
Functional operation above the stresses listed in the Recommended Operating Ranges is not implied. Extended exposure to stresses beyond
the Recommended Operating Ranges limits may affect device reliability.
*For voltage drops across the switch greater than 1.2 V (switch on), excessive VCC current may be drawn; i.e., the current out of the switch may
contain both VCC and switch input components. The reliability of the device will be unaffected unless the Maximum Ratings are exceeded.
DC ELECTRICAL CHARACTERISTIC Digital Section (Voltages Referenced to GND)
Symbol
Parameter
Test Conditions
VCC
V
Guaranteed Limit
Unit
– 55 to
25°C
v 85°C
v 125°C
VIH
Minimum HighLevel Voltage
ON/OFF Control Inputs
Ron = Per Spec
2.0
3.0
4.5
9.0
12.0
1.5
2.1
3.15
6.3
8.4
1.5
2.1
3.15
6.3
8.4
1.5
2.1
3.15
6.3
8.4
V
VIL
Maximum LowLevel Voltage
ON/OFF Control Inputs
Ron = Per Spec
2.0
3.0
4.5
9.0
12.0
0.5
0.9
1.35
2.7
3.6
0.5
0.9
1.35
2.7
3.6
0.5
0.9
1.35
2.7
3.6
V
Iin
Maximum Input Leakage Current
ON/OFF Control Inputs
Vin = VCC or GND
12.0
± 0.1
± 1.0
± 1.0
mA
ICC
Maximum Quiescent Supply Current
(per Package)
Vin = VCC or GND
VIO = 0 V
6.0
12.0
2
4
20
40
40
160
mA
This device contains protection
circuitry to guard against damage
due to high static voltages or electric
fields. However, precautions must
be taken to avoid applications of any
voltage higher than maximum rated
voltages to this highimpedance cir-
cuit. For proper operation, Vin and
Vout should be constrained to the
range GND v (Vin or Vout) v VCC.
Unused inputs must always be
tied to an appropriate logic voltage
level (e.g., either GND or VCC).
Unused outputs must be left open.
I/O pins must be connected to a
properly terminated line or bus.