Table 3. MAXIMUM RATINGS
Symbol
Parameter
Condition 1
Condition 2
Rating
Unit
V
CC
Positive Power Supply
GND = 0 V
V
EE
=
5.0 V
7
V
V
EE
Negative Power Supply
GND = 0 V
V
CC
= +5.0 V
8
V
V
IN
Input Voltage
GND = 0 V
V
I
V
CC
0 to V
CC
V
I
out
Output Current
Continuous
Surge
50
100
mA
mA
T
A
Operating Temperature Range
40 to +85
°
C
T
stg
Storage Temperature Range
65 to +150
°
C
JA
Thermal Resistance (Junction
to
Ambient)
0 lfpm
500 lfpm
SO
8
SO
8
190
130
°
C/W
°
C/W
JC
Thermal Resistance (Junction
to
Case)
Standard Board
SO
8
41 to 44
°
C/W
JA
Thermal Resistance (Junction
to
Ambient)
0 lfpm
500 lfpm
TSSOP
8
TSSOP
8
185
140
°
C/W
°
C/W
JC
Thermal Resistance (Junction
to
Case)
Standard Board
TSSOP
8
41 to 44
5%
°
C/W
JA
Thermal Resistance (Junction
to
Ambient)
0 lfpm
500 lfpm
DFN8
DFN8
129
84
°
C/W
°
C/W
T
sol
Wave Solder
Pb
Pb
Free
<2 to 3 sec @ 248
°
C
<2 to 3 sec @ 260
°
C
265
265
°
C
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may
affect device reliability.
Table 4. 10ELT SERIES NECL OUTPUT DC CHARACTERISTICS
V
CC
= 5.0 V; V
EE
=
5.0 V; GND = 0 V
(Note 2)
Symbol
Characteristic
40
°
C
25
°
C
85
°
C
Unit
Min
Typ
Max
Min
Typ
Max
Min
Typ
Max
I
CC
V
CC
Power Supply Current
7.0
4.5
7.0
7.0
mA
I
EE
Power Supply Current
18
12.5
18
18
mA
V
OH
Output HIGH Voltage (Note 3)
1080
990
890
980
895
810
910
815
720
mV
V
OL
Output LOW Voltage (Note 3)
1950
1800
1650
1950
1790
1630
1950
1773
1595
mV
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification
limit values are applied individually under normal operating conditions and not valid simultaneously.
2. Output parameters vary 1:1 with GND. V
CC
can vary 4.5 V / 5.5 V. V
EE
can vary
4.2 V /
5.5 V.
3. Outputs are terminated through a 50 resistor to GND
2 V.
Table 5. 100ELT SERIES NECL OUTPUT DC CHARACTERISTICS
V
CC
= 5.0 V; V
EE
=
5.0 V; GND = 0 V
(Note 4)
Symbol
Characteristic
40
°
C
25
°
C
85
°
C
Unit
Min
Typ
Max
Min
Typ
Max
Min
Typ
Max
I
CC
V
CC
Power Supply Current
7.0
4.5
7.0
7.0
mA
I
EE
Power Supply Current
18
12.5
18
18
mA
V
OH
Output HIGH Voltage (Note 5)
1085
1005
880
1025
955
880
1025
955
880
mV
V
OL
Output LOW Voltage (Note 5)
1830
1695
1555
1810
1705
1620
1810
1705
1620
mV
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification
limit values are applied individually under normal operating conditions and not valid simultaneously.
4. Output parameters vary 1:1 with GND. V
can vary 4.5 V / 5.5 V. V
EE
can vary
4.2 V /
5.5 V.
5. Outputs are terminated through a 50 resistor to GND
2 V.