MB95350L Series
22
DS07–12631–2E
(Continued)
R/W access symbols
Initial value symbols
Note: Do not write to an address that is “(Disabled)”. If a “(Disabled)” address is read, an indeterminate value
is returned.
Address
Register
abbreviation
Register name
R/W Initial value
0FBCH
BGR1
LIN-UART baud rate generator register 1
R/W
00000000B
0FBDH
BGR0
LIN-UART baud rate generator register 0
R/W
00000000B
0FBEH
PSSR0
UART/SIO dedicated baud rate generator prescaler select
register ch. 0
R/W
00000000B
0FBFH
BRSR0
UART/SIO dedicated baud rate generator baud rate setting
register ch. 0
R/W
00000000B
0FC0H
to
0FC2H
—
(Disabled)
—
0FC3H
AIDRL
A/D input disable register (lower)
R/W
00000000B
0FC4H
to
0FE3H
—
(Disabled)
—
0FE4H
CRTH
Main CR clock trimming register (upper)
R/W 0XXXXXXXB
0FE5H
CRTL
Main CR clock trimming register (lower)
R/W 00XXXXXXB
0FE6H,
0FE7H
—
(Disabled)
—
0FE8H
SYSC
System configuration register
R/W
11000001B
0FE9H
CMCR
Clock monitoring control register
R/W
00000000B
0FEAH
CMDR
Clock monitoring data register
R
00000000B
0FEBH
WDTH
Watchdog timer selection ID register (upper)
R
XXXXXXXXB
0FECH
WDTL
Watchdog timer selection ID register (lower)
R
XXXXXXXXB
0FEDH
—
(Disabled)
—
0FEEH
ILSR
Input level select register
R/W
00000000B
0FEFH
to
0FFFH
—
(Disabled)
—
R/W
: Readable / Writable
R
: Read only
W
: Write only
0
: The initial value of this bit is “0”.
1
: The initial value of this bit is “1”.
X