ABSOLUTE MAXIMUM RATINGS
Terminal Voltage (with respect to GND)
V
CC
......................................................................-0.3V to 6.0V
All Other Inputs.......................................-0.3V to (V
CC
+ 0.3V)
Input Current, V
CC,
MR ......................................................20mA
Output Current, RESET or RESET.......................................20mA
ELECTRICAL CHARACTERISTICS
(V
= 5V for L/M versions, V
= 3.3V for T/S versions, V
CC
= 3V for R version, T
A
= 0°C to +70°C, unless otherwise noted.
Typical values are at T
A
= +25°C.) (Note 1)
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
Continuous Power Dissipation (T
A
= +70°C)
SOT-143 (derate 4mW/°C above +70°C).....................320mW
Operating Temperature Range...............................0°C to +70°C
Storage Temperature Range.............................-65°C to +160°C
Lead Temperature (soldering, 10sec) .............................+300°C
I
SOURCE
= 150μA, 1.8V < V
CC
< V
TH(MIN)
MAX812R/S/T only, I
SINK
= 1.2mA,
V
CC
= V
TH(MAX)
MAX81_R/S/T, V
CC
= 3.6V, I
OUT
= 0A
MAX81_L
MAX81_M
MAX81_T
MAX81_S
MAX81_L/M, V
CC
= 5.5V, I
OUT
= 0A
V
OD
= 125mV, MAX81_R/S/T
V
CC
= V
TH(MAX)
V
OD
= 125mV, MAX81_L/M
MAX81_R
CONDITIONS
0.8V
CC
2.3
V
IH
V
IL
V
IH
μs
0.5
t
MD
MR to Reset Propagation Delay
(Note 2)
ns
100
MR Glitch Immunity (Note 3)
μs
10
t
MR
MR Minimum Pulse Width
ms
140
560
t
RP
Reset Active Timeout Period
μA
2.7
4.63
4.38
3.08
2.93
10
4.75
4.50
3.15
3.00
I
CC
Supply Current
6
15
V
1.0
5.5
V
CC
Range
μs
20
V
CC
to Reset Delay (Note 2)
40
ppm/°C
30
Reset Threshold Tempco
V
2.55
2.63
2.70
V
TH
Reset Threshold (Note 2)
4.50
4.25
3.00
2.85
UNITS
MIN
TYP
MAX
SYMBOL
PARAMETER
MAX812L/M only, I
SINK
= 3.2mA,
V
CC
= V
TH(MAX)
V
0.4
V
OL
RESET Output Voltage
(MAX812)
0.3
V
OH
V
CC
> V
TH(MAX)
, MAX81_L/M
0.8
V
CC
> V
TH(MAX)
, MAX81_R/S/T
V
0.25 x V
CC
V
IL
MR Input Threshold
0.7 x V
CC
k
10
20
30
MR Pull-Up Resistance