M
3-Pin, Ultra-Low-Power SC70/SOT
μP Reset Circuits
2
_______________________________________________________________________________________
ABSOLUTE MAXIMUM RATINGS
Terminal Voltage (with respect to GND)
V
CC
...........................................................................-0.3V to +6V
RESET,
RESET
(push-pull).........................-0.3V to (V
CC
+ 0.3V)
RESET
(open drain)..................................................-0.3V to +6V
Input Current (V
CC
).............................................................20mA
Output Current (RESET,
RESET
).........................................20mA
Rate of Rise (V
CC
)...........................................................100V/μs
ELECTRICAL CHARACTERISTICS
(V
CC
= full range, T
A
= -40°C to +85°C, unless otherwise noted. Typical values are at T
A
= +25°C and V
CC
= 3V.) (Note 1)
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
Continuous Power Dissipation (T
A
= +70°C)
3-Pin SC70 (derate 2.7mW/°C above +70°C)...............174mW
3-Pin SOT23 (derate 4mW/°C above +70°C)................320mW
Operating Temperature Range ...........................-40°C to +85°C
Storage Temperature Range.............................-65°C to +150°C
Lead Temperature (soldering, 10s).................................+300°C
Note 1:
Overtemperature limits are guaranteed by design and not production tested.
RESET Output Voltage
(MAX6327/MAX6347)
V
OL
0.4
I
SINK
= 3.2mA, V
CC
= V
TH(MAX)
, V
TH
≥
4.5V
MAX6326/MAX6327/MAX6328
0.4
I
SINK
= 3.2mA, V
CC
≥
4.5V, reset not asserted,
V
TH
≤
4.38V
V
V
OH
I
SOURCE
= 50μA, V
CC
≥
1.2V, reset asserted
I
SINK
= 1.2mA, V
CC
≥
3.2V, reset not asserted,
MAX6327 only
0.3
0.8
·
V
CC
0.8
·
V
CC
I
SOURCE
= 500μA, V
CC
≥
2.1V, reset asserted
1.0
1.75
V
TH
+
1.5%
μA
0.5
1.0
Supply Current
I
CC
V
CC
= 5.5V, no load
Reset Threshold
V
TH
-
1.5%
V
TH
V
V
TH
V
TH
-
2.5%
V
TH
V
TH
+
2.5%
Table 1
T
A
= +25°C
T
A
= -40°C to +85°C
1.2
5.5
1.0
5.5
0.8
·
V
CC
0.8
·
V
CC
0.8
·
V
CC
Open-Drain
RESET
Output
Leakage Current
μA
0.1
RESET Threshold
Hysteresis
mV
9.5
MAX6346/MAX6347/MAX6348
6.3
V
CC
to Reset Delay
Reset Active Timeout Period
RESET
Output Voltage
(MAX6326/MAX6328/
MAX6346/MAX6348)
20
185
μs
ms
V
CC
= V
TH
to (V
TH
- 100mV)
PARAMETER
SYMBOL
MIN
TYP
MAX
UNITS
100
280
V
CC
Range
V
Reset Threshold Tempco
V
TH
/°C
40
ppm/°C
CONDITIONS
T
A
= 0°C to +70°C
T
A
= -40°C to +85°C
MAX632_ only, V
CC
= 3.0V for V
TH
≤
2.93V,
V
CC
= 3.2V for V
TH
> 2.93V, no load
V
I
SOURCE
= 800μA, V
CC
= V
TH(MAX)
, V
TH
≥
4.5V
RESET
Output Voltage
(MAX6326/MAX6346)
I
SOURCE
= 800μA, V
CC
= 4.5V, V
TH
≤
4.38V
V
OH
I
SOURCE
= 500μA, V
CC
= 3.2V, MAX6326 only
V
0.3
I
SINK
= 1.6mA, V
CC
> 2.1V, reset asserted
V
OL
0.4
I
SINK
= 100μA, V
CC
≥