MAX6326/MAX6327/MAX6328/MAX6346/MAX6347/MAX6348
3-Pin, Ultra-Low-Power SC70/SOT
P Reset Circuits
2
_______________________________________________________________________________________
ABSOLUTE MAXIMUM RATINGS
ELECTRICAL CHARACTERISTICS
(VCC = full range, TA = -40°C to +85°C, unless otherwise noted. Typical values are at TA = +25°C and VCC = 3V.) (Note 1)
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
Terminal Voltage (with respect to GND)
VCC ...........................................................................-0.3V to +6V
RESET, RESET (push-pull) .........................-0.3V to (VCC + 0.3V)
RESET (open drain)..................................................-0.3V to +6V
Input Current (VCC) .............................................................20mA
Output Current (RESET, RESET).........................................20mA
Rate of Rise (VCC) ...........................................................100V/s
Continuous Power Dissipation (TA = +70°C)
3-Pin SC70 (derate 2.7mW/°C above +70°C) ...............174mW
3-Pin SOT23 (derate 4mW/°C above +70°C)................320mW
Operating Temperature Range ...........................-40°C to +85°C
Storage Temperature Range .............................-65°C to +150°C
Lead Temperature (soldering, 10s) .................................+300°C
Note 1: Overtemperature limits are guaranteed by design and not production tested.
RESET Output Voltage
(MAX6327/MAX6347)
VOL
0.4
ISINK = 3.2mA, VCC = VTH(MAX), VTH
≥ 4.5V
0.4
ISINK = 3.2mA, VCC
≥ 4.5V, reset not asserted,
VTH
≤ 4.38V
V
VOH
ISOURCE = 50A, VCC
≥ 1.2V, reset asserted
0.3
ISINK = 1.2mA, VCC
≥ 3.2V, reset not asserted,
MAX6327 only
0.8 VCC
ISOURCE = 500A, VCC
≥ 2.1V, reset asserted
1.0
1.75
A
0.5
1.0
Supply Current
ICC
VCC = 5.5V, no load
Reset Threshold
VTH -
VTH
VTH +
1.5%
V
VTH
VTH -
VTH
VTH +
2.5%
Table 1
TA = +25°C
TA = -40°C to +85°C
1.2
5.5
1.0
5.5
0.8 VCC
Open-Drain RESET Output
Leakage Current
A
0.1
RESET Threshold
Hysteresis
mV
9.5
MAX6346/MAX6347/MAX6348
6.3
MAX6326/MAX6327/MAX6328
VCC to Reset Delay
20
s
VCC = VTH to (VTH - 100mV)
PARAMETER
SYMBOL
MIN
TYP
MAX
UNITS
ms
100
185
280
VCC Range
V
Reset Threshold Tempco
VTH/°C
40
ppm/°C
CONDITIONS
TA = 0°C to +70°C
TA = -40°C to +85°C
V
Reset Active Timeout Period
ISOURCE = 800A, VCC = VTH(MAX), VTH
≥ 4.5V
RESET Output Voltage
(MAX6326/MAX6346)
ISOURCE = 800A, VCC = 4.5V, VTH
≤ 4.38V
VOH
ISOURCE = 500A, VCC = 3.2V, MAX6326 only
MAX632_ only, VCC = 3.0V for VTH
≤ 2.93V,
VCC = 3.2V for VTH > 2.93V, no load
V
0.3
ISINK = 1.6mA, VCC > 2.1V, reset asserted
RESET Output Voltage
(MAX6326/MAX6328/
MAX6346/MAX6348)
VOL
0.4
ISINK = 100A, VCC
≥ 1.2V, reset asserted