M
Fault-Protected, Low-Voltage,
Quad SPST Analog Switches
_______________________________________________________________________________________
7
ELECTRICAL CHARACTERISTICS—+3V Single Supply (continued)
(V+ = +2.7V to +3.6V, V- = 0, V
IH
= +2.0V, V
IL
= +0.6V, GND = 0, T
A
= T
MIN
to T
MAX
, unless otherwise noted. Typical values are at
T
A
= +25°C.) (Note 3)
PARAMETER
SYMBOL
CONDITIONS
T
A
MIN
TYP
MAX
UNITS
LOGIC INPUT
Input Logic High
Input Logic Low
Input-Leakage Current (Note 5)
SWITCH DYNAMICS
V
IH
V
IL
I
IN
_
C, E
C, E
C, E
2
V
V
μA
0.6
+5
V
IN
_ = 0 or V+
-5
+25
°
C
C, E
+25
°
C
C, E
+25
°
C
C, E
340
500
600
175
225
Turn-On Time
t
ON
V+ = +2.7V, V
NO
_ or V
NC
_ = +1.5V
R
L
= 300
, C
L
= 35pF, Fi gur e 2
ns
100
Turn-Off Time
t
OFF
V+ = +2.7V, V
NO
_ or V
NC
_ = +1.5V
R
L
= 300
, C
L
= 35pF, Fi gur e 2
ns
60
50
240
Break-Before-Make Time Delay
(MAX4713 only)
POWER SUPPLY
Power-Supply Range
t
BBM
V+ = +2.7V, V
NO
_ or V
NC
_ = +1.5V
R
L
= 300
, C
L
= 35pF, Fi gur e 2
ns
V+
C, E
+25
°
C
C, E
2.7
11
15
20
V
8
V+ Supply Current
I+
All V
IN
_ = 0 or V+
μA
Note 3:
Algebraic convention is used in this data sheet; the most negative value is shown in the minimum column.
Note 4:
R
ON
=
R
ON
(MAX) -
R
ON
(MIN)
Note 5:
Leakage parameters are 100% tested at maximum-rated temperature and with dual supplies. Leakage parameters are
guaranteed by correlation at +25°C.
Note 6:
Off-isolation = 20 log
10
[V
COM_
/(V
NO_
or V
NC_
)], V
COM_
= output, V
NO_
or V
NC_
= input to off switch.
Note 7: