Note 3: The algebraic convention is used in this data sheet; the most negative value is shown in the minimum column.
Note 4:
RON = RON(MAX) - RON(MIN).
Note 5: Leakage parameters are 100% tested at maximum-rated hot temperature and guaranteed by correlation at TA = +25°C.
Note 6: Guaranteed by design.
Note 7: Off-isolation = 20log10(VCOM_ / VNO_), VCOM_ = output, VNO_ = input to off switch.
Note 8: Between any two analog inputs.
Note 9: Leakage testing for single-supply operation is guaranteed by testing with dual supplies.
ELECTRICAL CHARACTERISTICS—Single Supply (continued)
(V+ = +12V, V- = 0, TA = TMIN to TMAX, unless otherwise noted. Typical values are at TA = +25°C.) (Note 3)
CONDITIONS
TA
+25°C
200
500
VCOM_ = +10V,
RL = 2k
; Figure 2
tON
Turn-On Time
ns
C, E, M
+25°C
550
350
f = 1MHz; Figure 5
C, E, M
CCOM_(ON)
1000
RL = 50
, CL = 15pF,
VNO_ = 1VRMS, f = 1MHz;
Figure 6
f = 1MHz; Figure 5
VISO
CN_(OFF)
Off-Isolation (Note 7)
NO_ or NC_ Off-Capacitance
dB
A
pF
All VIN_ = 0 or +5V,
VNO_ = VNC_ = 0
C, E, M
IGND
+25°C
V- and GND Supply Current
5
100
936
VCOM_ = +10V,
RL = 1k
; Figure 3
V
tBBM
Break-Before-Make Time Delay
ns
+25°C
5
RL = 50
, CL = 15pF,
VNO_ = 1VRMS, f = 1MHz;
Figure 6
COM_ On-Capacitance
+25°C
VCT
UNITS
MIN
TYP
MAX
SYMBOL
PARAMETER
Channel-to-Channel Crosstalk
(Note 8)
-62
pF
dB
+25°C
15
-65
V+
Power-Supply Range
C, E, M
+25°C
350
200
A
All VIN_ = 0 or +12V,
VNO_ = VNC_ = 0
C, E, M
+25°C
550
350
A
All VIN_ = 0 or +5V,
VNO_ = VNC_ = 0
I+
V+ Supply Current
+25°C
2
CL = 100pF,
VCOM_ = 0; Figure 4
Q
pC
Charge Injection
+25°C
100
300
VCOM_ = +10V,
RL = 2k
; Figure 2
tOFF
Turn-Off Time
ns
C, E, M
900
SWITCH DYNAMIC CHARACTERISTICS
POWER SUPPLY