參數(shù)資料
型號(hào): MAX1617AMEE+T
廠商: Maxim Integrated
文件頁(yè)數(shù): 11/20頁(yè)
文件大?。?/td> 292K
描述: IC REMOTE/LOCAL TEMP SNSR 16QSOP
產(chǎn)品培訓(xùn)模塊: Lead (SnPb) Finish for COTS
Obsolescence Mitigation Program
標(biāo)準(zhǔn)包裝: 2,500
功能: 溫度計(jì),恒溫計(jì)
傳感器類型: 內(nèi)部和外部
感應(yīng)溫度: -55°C ~ 125°C,外部傳感器
精確度: ±3°C(最小值)
拓?fù)洌?/td> ADC,比較器,多路復(fù)用器,寄存器庫(kù)
輸出類型: I²C?/SMBus?
輸出警報(bào):
輸出風(fēng)扇:
電源電壓: 3 V ~ 5.5 V
工作溫度: -55°C ~ 125°C
安裝類型: 表面貼裝
封裝/外殼: 16-SSOP(0.154",3.90mm 寬)
供應(yīng)商設(shè)備封裝: 16-QSOP
包裝: 帶卷 (TR)
Alarm Threshold Registers
Four registers store alarm threshold data, with high-
temperature (T
HIGH
) and low-temperature (T
LOW
) reg-
isters for each A/D channel. If either measured
temperature equals or exceeds the corresponding
alarm threshold value, an ALERT interrupt is asserted.
The power-on-reset (POR) state of both T
HIGH
registers
is full scale (0111 1111, or +127癈). The POR state of
both T
LOW
registers is 1100 1001 or -55癈.
Diode Fault Alarm
There is a continuity fault detector at DXP that detects
whether the remote diode has an open-circuit condi-
tion. At the beginning of each conversion, the diode
fault is checked, and the status byte is updated. This
fault detector is a simple voltage detector; if DXP rises
above V
CC
- 1V (typical) due to the diode current
source, a fault is detected. Note that the diode fault
isnt checked until a conversion is initiated, so immedi-
ately after power-on reset the status byte indicates no
fault is present, even if the diode path is broken.
If the remote channel is shorted (DXP to DXN or DXP to
GND), the ADC reads 0000 0000 so as not to trip either
the T
HIGH
or T
LOW
alarms at their POR settings. In
applications that are never subjected to 0癈 in normal
operation, a 0000 0000 result can be checked to indi-
cate a fault condition in which DXP is accidentally short
circuited. Similarly, if DXP is short circuited to V
CC
, the
ADC reads +127癈 for both remote and local channels,
and the device alarms.
AALLEERRTT Interrupts
The ALERT interrupt output signal is latched and can
only be cleared by reading the Alert Response address.
Interrupts are generated in response to T
HIGH
and T
LOW
comparisons and when the remote diode is disconnect-
ed (for continuity fault detection). The interrupt does not
halt automatic conversions; new temperature data con-
tinues to be available over the SMBus interface after
ALERT is asserted. The interrupt output pin is open-drain
so that devices can share a common interrupt line. The
interrupt rate can never exceed the conversion rate.
The interface responds to the SMBus Alert Response
address, an interrupt pointer return-address feature
(see Alert Response Address section). Prior to taking
corrective action, always check to ensure that an inter-
rupt is valid by reading the current temperature.
Alert Response Address
The SMBus Alert Response interrupt pointer provides
quick fault identification for simple slave devices that
lack the complex, expensive logic needed to be a bus
master. Upon receiving an ALERT interrupt signal, the
host master can broadcast a Receive Byte transmission
to the Alert Response slave address (0001 100). Then
any slave device that generated an interrupt attempts
to identify itself by putting its own address on the bus
(Table 3).
11
Remote/Local Temperature Sensor
with SMBus Serial Interface
MAX1617A
Maxim Integrated
DIGITAL OUTPUT
DATA BITS
0
111
1111
+127
+127.00
0
111
1111
0
111
1110
+126
+126.00
+127
+126.50
0
001
1001
0
000
0001
+1
+0.50
0
000
0000
0
000
0000
0
0.00
ROUNDED
TEMP.
(癈)
TEMP.
(癈)
0
+0.25
+25
+25.25
0
000
0000
0
000
0000
0
-0.50
1
111
1111
1
111
1111
-1
-1.00
-1
-0.75
1
110
0111
1
110
0110
-26
-25.50
1
100
1001
1
100
1001
-55
-55.00
0
-0.25
-55
-54.75
-25
-25.00
1
011
1111
1
011
1111
-65
-70.00
-65
-65.00
Table 2. Data Format (Twos Complement)
Table 3. Read Format for Alert Response
Address (0001100)
ADD6
6
Provide the current MAX1617A
slave address that was latched at
POR (Table 8)
FUNCTION
ADD5
5
ADD4
4
ADD3
3
ADD2
2
ADD1
1
ADD7
7
(MSB)
1
0
(LSB)
Logic 1
BIT
NAME
SIGN
MSB
LSB
0
111
1111
+127
+130.00
相關(guān)PDF資料
PDF描述
MAX1617MEE+T IC REMOTE/LOCAL TEMP SNSR 16QSOP
MAX1619MEE+ IC TEMP SENSOR W/ALARM 16-QSOP
MAX1765EUE+ IC REG DL BST/LINEAR 16TSSOP
MAX1989MUE+ IC TEMP SENSOR REMOTE 16TSSOP
MAX31723MUA+ IC THERMOMETER/STAT SPI-3W 8UMAX
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
MAX1617DBR2 制造商:ON Semiconductor 功能描述:Temp Sensor Digital Serial (2-Wire) 16-Pin QSOP T/R 制造商:Rochester Electronics LLC 功能描述:- Bulk
MAX1617MEE 功能描述:板上安裝溫度傳感器 RoHS:否 制造商:Omron Electronics 輸出類型:Digital 配置: 準(zhǔn)確性:+/- 1.5 C, +/- 3 C 溫度閾值: 數(shù)字輸出 - 總線接口:2-Wire, I2C, SMBus 電源電壓-最大:5.5 V 電源電壓-最小:4.5 V 最大工作溫度:+ 50 C 最小工作溫度:0 C 關(guān)閉: 安裝風(fēng)格: 封裝 / 箱體: 設(shè)備功能:Temperature and Humidity Sensor
MAX1617MEE+ 功能描述:板上安裝溫度傳感器 Remote/Local w/SMBus Serial Interface RoHS:否 制造商:Omron Electronics 輸出類型:Digital 配置: 準(zhǔn)確性:+/- 1.5 C, +/- 3 C 溫度閾值: 數(shù)字輸出 - 總線接口:2-Wire, I2C, SMBus 電源電壓-最大:5.5 V 電源電壓-最小:4.5 V 最大工作溫度:+ 50 C 最小工作溫度:0 C 關(guān)閉: 安裝風(fēng)格: 封裝 / 箱體: 設(shè)備功能:Temperature and Humidity Sensor
MAX1617MEE+T 功能描述:板上安裝溫度傳感器 Remote/Local w/SMBus Serial Interface RoHS:否 制造商:Omron Electronics 輸出類型:Digital 配置: 準(zhǔn)確性:+/- 1.5 C, +/- 3 C 溫度閾值: 數(shù)字輸出 - 總線接口:2-Wire, I2C, SMBus 電源電壓-最大:5.5 V 電源電壓-最小:4.5 V 最大工作溫度:+ 50 C 最小工作溫度:0 C 關(guān)閉: 安裝風(fēng)格: 封裝 / 箱體: 設(shè)備功能:Temperature and Humidity Sensor
MAX1617MEE+TW 功能描述:板上安裝溫度傳感器 Remote/Local Temperature Sensor with SMBus Serial Interface RoHS:否 制造商:Omron Electronics 輸出類型:Digital 配置: 準(zhǔn)確性:+/- 1.5 C, +/- 3 C 溫度閾值: 數(shù)字輸出 - 總線接口:2-Wire, I2C, SMBus 電源電壓-最大:5.5 V 電源電壓-最小:4.5 V 最大工作溫度:+ 50 C 最小工作溫度:0 C 關(guān)閉: 安裝風(fēng)格: 封裝 / 箱體: 設(shè)備功能:Temperature and Humidity Sensor