Broadband CATV Amplifier
50 - 1000 MHz
MAAMSS0042
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
North America
Tel: 800.366.2266 / Fax: 978.366.2266
Europe
Tel: 44.1908.574.200 / Fax: 44.1908.574.300
Asia/Pacific
Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com
for additional data sheets and product information.
V2
1
Compliant
RoHS
Functional Schematic
Features
75
Ω
Input / Output Match
-70 dBc CTB
3.0 dB Noise Figure
15 dB Gain
Lead-Free SOT-89 Package
100% Matte Tin Plating over Copper
Halogen-Free “Green” Mold Compound
RoHS* Compliant and 260°C Reflow Compatible
Description
M/A-COM’s MAAMSS0042 CATV amplifier is a
GaAs MMIC which exhibits low distortion in a
lead-free miniature surface mount plastic package.
The MAAMSS0042 employs a monolithic single
stage design featuring a convenient 75
Ω
input/
output impedance that minimizes the number of
external components required.
The MAAMSS0042 provides low noise and high
linearity. It is ideally suited for set top boxes, home
gateways, FTTX, Drop Amplifiers, and other
broadband internet based appliances.
The MAAMSS0042 is fabricated using M/A-COM’s
PHEMT process to realize low noise and low
distortion. The process features full passivation for
robust performance and reliability.
Absolute Maximum Ratings
2,3
Parameter
Absolute Maximum
RF Input Power
10 dBm
Voltage
10.0 volts
Operating Temperature
-20 °C to +85 °C
Storage Temperature
-65 °C to +150 °C
Pin Configuration
Pin No.
Pin Name
Description
1
RF
IN
RF Input
2
GND
Ground
3
RF
OUT
RF Output / Drain Supply
RF
IN
RF
OUT
Pin 1
GND
GND
Ordering Information
1
Part Number
Package
MAAMSS0042
Bulk Packaging
MAAMSS0042TR
1000 piece reel
MAAMSS0042TR-3000
3000 piece reel
MAAMSS0042SMB
Sample Test Board
(Includes 5 Samples)
2. Exceeding any one or combination of these limits may cause
permanent damage to this device.
3. M/A-COM does not recommend sustained operation near
these survivability limits.
* Restrictions on Hazardous Substances, European Union Directive 2002/95/EC.
1. Reference Application Note M513 for reel size information.