![](http://datasheet.mmic.net.cn/180000/M83733-7RA051_datasheet_11317875/M83733-7RA051_16.png)
MIL-C-83733
DPK
Assembly/Shielded Contacts
92
www.ittcannon.com
Dimensions shown in inch (mm)
Specifications and dimensions subject to change
Socket
249-1826-000/MIL-C-39029/51
Size 12/RG-179B/U Cable (used in 71C15 layout
249-1826-000/MIL-C-39029/50
Size 12/RG-179B/U Cable (used in 71C15 layout
FERRULE
.084 MIN. DIA.
(2.13)
BODY
INSULATOR
INNER SKT CONTACT
INNER PIN CONTACT
FERRULE
.403 REF.
(10.24)
INNER
CONTACT
Strip outer jacket to dimensions shown to expose outer conductor.
Slip (or install) ferrule over outer conductor against cable jacket.
Exposed portion of the outer conductor must be combed out then
folded back over ferrule.
Trim cable to dimensions, as shown. (Ferrule must butt against
cable jacket).
Insert cable,ferrule and inner contact to rear of shell and crimp
into place with M22520/5-03 crimp tool.
Install inner contact against dielectric then crimp contact and center
conductor with a M22520/2-01 cimp tool using a M22520/2-30
locator.
DIELECTRIC
OUTER CONDUCTOR SHALL
NOT EXCEED THIS EDGE
.122 MIN. DIA.
(3.10)
.122 MIN. DIA.
(3.10)
Pin
Step 1.
Step 2.
Step 3.
Step 5.
Step 4.
.148 ± .002 DIA.
(3.75 ± 0.05)
.148 ± .002 DIA.
(3.75 ± 0.05)
.046 ± .002
(1.16 ± 0.05)
.510 ± .010
(12.95 ± 0.25)
.118 ± .003
(3.00 ± 0.08)
.094 ± .001
(2.38 ± 0.02)
.340 ± .010
(8.64 ± 0.25)
.070 ± .010
(1.78 ± 0.25)
.151 MAX. DIA.
(3.84)
.616 ± .005
(15.64 ± 0.13)
.880 MAX.
(22.35)
.046 ± .002
(1.16 ± 0.50)
.495 ± .005
(12.57 ± 0.13)
.160 ± .001
(4.06 ± 0.02)
.187 ± .002 DIA.
(4.74 ± 0.05)
.187 ± .002 DIA.
(4.74 ± 0.05)
.756 MAX.
(19.20)
.084 ± .MIN. DIA.
(2.13)
Assembly Instructions