13
Measure the time needed for the output pulse to fall from 90% to 10% (OTf) with an active prove.
Measure the time needed for the output pulse to rise from 10% to 90% (OTr) with an active prove.
Measure the amplitude output at OUT(2,5,9). The measured value is called VOUT(2,5,9),
and is treated as Oaj1.
Oaj1 = VOUT(2) / VOUT(5), VOUT(5) / VOUT(9), VOUT(9) / VOUT(2)
Relative characteristics Oaj1 is calculated by the equation below:
47)
48)
Measuring condition and procedure are the same as described in Note49.
Measuring condition and procedure are the same as described in Note51.
49)
50)
Measuring the amplitude output at OUT(2,5,9). The measured value is called O
BLK
.
Relative OSD BLK characteristics O
BLK
is calculated by the equation below:
55)
56)
Reduce the SG5 input level gradually, monitoring output.Measure the SG5 level
when the output reaches 0V. The measured value is called VthOSD.
Confirm that output signal is being blanked by the SG5 at the time.
Monitoring to output signal, decreasing the level of SG5. Measure the top level of SG6
when the blanking period is disappeared. The measured value is called VthBLK.
57)
58)
O
BLK
= VOUT(2) / VOUT(5), VOUT(5) / VOUT(9), VOUT(9) / VOUT(2)
51)
52)
53)
54)
59)
60)
61)
62)
63)
64)
65)
66)
67)
68)
Measuring condition and procedure are the same as described in Note49.
Measuring condition and procedure are the same as described in Note51.
Measuring condition and procedure are the same as described in Note49.
Measuring condition and procedure are the same as described in Note49.
Supply 5V to V19,and then measure input current into Pin19
Supply 0V to V19,and then measure input current into Pin19
Supply 5V to V20,and then measure input current into Pin20
Supply 0V to V20,and then measure input current into Pin20
Supply 5V to V(24,25,26)and then measure input current into Pin(24,25,26)
Supply 0V to V(24,25,26)and then measure input current into Pin(24,25,26)
Supply 5V to V27,and then measure input current into Pin27
Supply 0V to V27,and then measure input current into Pin27
69)
70)
Measuring condition and procedure are the same as described in Note49.
Measuring condition and procedure are the same as described in Note51.