LTC1659
4
1659fa
ELECTRICAL CHARACTERISTICS The ● denotes the specications which apply over the full operating
temperature range, otherwise specications are at TA = 25°C. VCC = 2.7V to 5.5V, VOUT unloaded, REF ≤ VCC, TA = TMIN to TMAX
unless otherwise noted.
SYMBOL
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
Switching (VCC = 4.5V to 5.5V
t1
DIN Valid to CLK Setup
●
40
ns
t2
DIN Valid to CLK Hold
●
0ns
t3
CLK High Time
(Note 7)
●
40
ns
t4
CLK Low Time
(Note 7)
●
40
ns
t5
CS/LD Pulse Width
(Note 7)
●
50
ns
t6
LSB CLK to CS/LD
(Note 7)
●
40
ns
t7
CS/LD Low to CLK
(Note 7)
●
20
ns
t8
DOUT Output Delay
CLOAD = 15pF
●
5150
ns
t9
CLK Low to CS/LD Low
(Note 7)
●
20
ns
Switching (VCC = 2.7V to 5.5V)
t1
DIN Valid to CLK Setup
●
60
ns
t2
DIN Valid to CLK Hold
●
0ns
t3
CLK High Time
(Note 7)
●
60
ns
t4
CLK Low Time
(Note 7)
●
60
ns
t5
CS/LD Pulse Width
(Note 7)
●
80
ns
t6
LSB CLK to CS/LD
(Note 7)
●
60
ns
t7
CS/LD Low to CLK
(Note 7)
●
30
ns
t8
DOUT Output Delay
CLOAD = 15pF
●
10
220
ns
t9
CLK Low to CS/LD Low
(Note 7)
●
30
ns
Note 1: Stresses beyond those listed under Absolute Maximum Ratings
may cause permanent damage to the device. Exposure to any Absolute
Maximum Rating condition for extended periods may affect device
reliability and lifetime.
Note 2: Nonlinearity is dened from code 20 to code 4095 (full scale). See
Applications Information.
Note 3: Load is 5k
Ω in parallel with 100pF.
Note 4: DAC switched between all 1s and the code corresponding to VOS
for the part.
Note 5: Digital inputs at 0V or VCC.
Note 6: VOUT can only swing from (GND + |VOS|) to (VCC – |VOS|) when
output is unloaded.