參數(shù)資料
型號(hào): LT1168CS8
廠商: Linear Technology
文件頁數(shù): 7/20頁
文件大小: 0K
描述: IC AMP INSTR PROG PREC LP 8SOIC
標(biāo)準(zhǔn)包裝: 100
放大器類型: 儀表
電路數(shù): 1
轉(zhuǎn)換速率: 0.5 V/µs
增益帶寬積: 400kHz
電流 - 輸入偏壓: 80pA
電壓 - 輸入偏移: 20µV
電流 - 電源: 350µA
電流 - 輸出 / 通道: 32mA
電壓 - 電源,單路/雙路(±): 4.6 V ~ 36 V,±2.3 V ~ 18 V
工作溫度: 0°C ~ 70°C
安裝類型: 表面貼裝
封裝/外殼: 8-SOIC(0.154",3.90mm 寬)
供應(yīng)商設(shè)備封裝: 8-SO
包裝: 管件
15
LT1168
1168fa
voltages or high levels of noise. Typically, the sources of
these very small signals (on the order of microvolts or
millivolts) are sensors that can be a significant distance
from the signal conditioning circuit. Although these sen-
sors may be connected to signal conditioning circuitry,
using shielded or unshielded twisted-pair cabling, the ca-
bling may act as antennae, conveying very high frequency
interference directly into the input stage of the LT1168.
The amplitude and frequency of the interference can have
an adverse effect on an instrumentation amplifier’s input
stage by causing an unwanted DC shift in the amplifier’s
input offset voltage. This well known effect is called RFI
rectification and is produced when out-of-band interfer-
ence is coupled (inductively, capacitively or via radiation)
and rectified by the instrumentation amplifier’s input tran-
sistors. These transistors act as high frequency signal
detectors, in the same way diodes were used as RF
envelope detectors in early radio designs. Regardless of
the type of interference or the method by which it is
coupled into the circuit, an out-of-band error signal ap-
pears in series with the instrumentation amplifier’s inputs.
To significantly reduce the effect of these out-of-band
signals on the input offset voltage of instrumentation
amplifiers, simple lowpass filters can be used at the
inputs. This filter should be located very close to the input
pins of the circuit. An effective filter configuration is
illustrated in Figure 7, where three capacitors have been
added to the inputs of the LT1168. Capacitors CXCM1 and
CXCM2 form lowpass filters with the external series resis-
tors RS1, 2 to any out-of-band signal appearing on each of
the input traces. Capacitor CXD forms a filter to reduce any
unwanted signal that would appear across the input traces.
An added benefit to using CXD is that the circuit’s AC
common mode rejection is not degraded due to common
mode capacitive imbalance. The differential mode and
common mode time constants associated with the capaci-
tors are:
tDM(LPF) = (RS1 + RS2)(CXD + CXCM1 + CXCM2)
tCM(LPF) = (RS1||RS2)(CXCM1+ CXCM2)
Setting the time constants requires a knowledge of the
frequency, or frequencies of the interference. Once this
frequency is known, the common mode time constants
can be set followed by the differential mode time constant.
To avoid any possibility of inadvertently affecting the
signal to be processed, set the common mode time
constant an order of magnitude (or more) smaller than the
differential mode time constant. Set the common mode
time constants such that they do not degrade the LT1168
inherent AC CMR. Then the differential mode time con-
stant can be set for the bandwidth required for the appli-
cation. Setting the differential mode time constant close to
the sensor’s BW also minimizes any noise pickup along
the leads. To avoid any possibility of common mode to
differential mode signal conversion, match the common
mode time constants to 1% or better. If the sensor is an
RTD or a resistive strain gauge and is in proximity to the
instrumentation amplifier, then the series resistors RS1, 2
can be omitted.
Figure 7. Adding a Simple RC Filter at the Inputs to an
Instrumentation Amplifier is Effective in Reducing Rectification
of High Frequency Out-of-Band Signals
APPLICATIO S I FOR ATIO
WU
UU
–VS
+VS
IN +
IN
1168 F07
VOUT
RG
CXCM1
0.001
F
CXCM2
0.001
F
CXD
0.1
F
RS1
1.6k
RS2
1.6k
EXTERNAL RFI
FILTER
+
LT1168
f–3dB ≈ 500Hz
Nerve Impulse Amplifier
The LT1168’s low current noise makes it ideal for EMG
monitors that have high source impedances. Demonstrat-
ing the LT1168’s ability to amplify low level signals, the
circuit in Figure 8 takes advantage of the amplifier’s high
gain and low noise operation. This circuit amplifies the low
level nerve impulse signals received from a patient at
Pins 2 and 3. RG and the parallel combination of R3 and R4
set a gain of ten. The potential on LT1112’s Pin 1 creates
相關(guān)PDF資料
PDF描述
LT1352CN8 IC OP-AMP HI-SPD 3MHZ DUAL 8-DIP
7LET FUSE 7A 240V SEMI PROTECT TYPE T
929647-07-25-I CONN HEADER .100 SNGL STR 25POS
LT1013IN8 IC PRECISION OP-AMP DUAL 8-DIP
ALD4701PBL IC OPAMP GP R-R CMOS QUAD 14PDIP
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
LT1168CS8#PBF 功能描述:IC AMP INSTR PREC PROG 8-SOIC RoHS:是 類別:集成電路 (IC) >> Linear - Amplifiers - Instrumentation 系列:- 標(biāo)準(zhǔn)包裝:2,500 系列:- 放大器類型:通用 電路數(shù):4 輸出類型:- 轉(zhuǎn)換速率:0.6 V/µs 增益帶寬積:1MHz -3db帶寬:- 電流 - 輸入偏壓:45nA 電壓 - 輸入偏移:2000µV 電流 - 電源:1.4mA 電流 - 輸出 / 通道:40mA 電壓 - 電源,單路/雙路(±):3 V ~ 32 V,±1.5 V ~ 16 V 工作溫度:0°C ~ 70°C 安裝類型:表面貼裝 封裝/外殼:14-TSSOP(0.173",4.40mm 寬) 供應(yīng)商設(shè)備封裝:14-TSSOP 包裝:帶卷 (TR) 其它名稱:LM324ADTBR2G-NDLM324ADTBR2GOSTR
LT1168CS8#PBF 制造商:Linear Technology 功能描述:INSTR-AMPLIFIER 400KHZ SOIC- 制造商:Linear Technology 功能描述:INSTR-AMPLIFIER, 400KHZ, SOIC-8
LT1168CS8#TR 功能描述:IC AMP INSTR PROG PREC LP 8SOIC RoHS:否 類別:集成電路 (IC) >> Linear - Amplifiers - Instrumentation 系列:- 標(biāo)準(zhǔn)包裝:73 系列:Over-The-Top® 放大器類型:通用 電路數(shù):4 輸出類型:滿擺幅 轉(zhuǎn)換速率:0.07 V/µs 增益帶寬積:200kHz -3db帶寬:- 電流 - 輸入偏壓:1nA 電壓 - 輸入偏移:285µV 電流 - 電源:50µA 電流 - 輸出 / 通道:25mA 電壓 - 電源,單路/雙路(±):2 V ~ 44 V,±1 V ~ 22 V 工作溫度:-40°C ~ 85°C 安裝類型:表面貼裝 封裝/外殼:16-WFDFN 裸露焊盤 供應(yīng)商設(shè)備封裝:16-DFN-EP(5x3) 包裝:管件
LT1168CS8#TRPBF 功能描述:IC AMP INSTR PROG PREC LP 8SOIC RoHS:是 類別:集成電路 (IC) >> Linear - Amplifiers - Instrumentation 系列:- 標(biāo)準(zhǔn)包裝:73 系列:Over-The-Top® 放大器類型:通用 電路數(shù):4 輸出類型:滿擺幅 轉(zhuǎn)換速率:0.07 V/µs 增益帶寬積:200kHz -3db帶寬:- 電流 - 輸入偏壓:1nA 電壓 - 輸入偏移:285µV 電流 - 電源:50µA 電流 - 輸出 / 通道:25mA 電壓 - 電源,單路/雙路(±):2 V ~ 44 V,±1 V ~ 22 V 工作溫度:-40°C ~ 85°C 安裝類型:表面貼裝 封裝/外殼:16-WFDFN 裸露焊盤 供應(yīng)商設(shè)備封裝:16-DFN-EP(5x3) 包裝:管件
LT1168I 制造商:LINER 制造商全稱:Linear Technology 功能描述:Low Power, Single Resistor Gain Programmable, Micropower Precision Instrumentation Amplifier