LT1017/LT1018
4
10178ff
ELECTRICAL CHARACTERISTICS The l denotes the specications which apply over the full operating
temperature range of – 55°C to 85°C for M grade parts, –40°C to 85°C for I grade parts and 0°C to 70°C for C grade parts.
PARAMETER
CONDITIONS
MIN
LT1017
TYP
MAX
MIN
LT1018
TYP
MAX
UNITS
Leakage Current
VS = 5V, VOUT = 40V
VIN ≥ 100mV
25°C
●
125°C
0.5
0.6
3
5
1
1.8
8
10
15
μA
Supply Current
VS = 5V
25°C
●
125°C
30
40
60
80
110
250
300
μA
VS = 40V
25°C
●
125°C
40
55
90
100
130
140
250
270
300
μA
Minimum Operating Voltage
IOUT = 1mA
25°C
●
125°C
1.15
1.2
V
Note 1: Stresses beyond those listed under Absolute Maximum Ratings
may cause permanent damage to the device. Exposure to any Absolute
Maximum Rating condition for extended periods may affect device
reliability and lifetime.
Note 2: Offset voltage is guaranteed over a common mode voltage range
of V– ≤ VIN ≤ (V+ – 0.9V).
Note 3: No load gain is guaranteed but not tested (LT1017 only).