The functional differences between LS7631 and LS7632 are:
LS7631
- When a LONG touch is applied, the dimming direction auto-
matically reverses whenever maximum or minimum conduction an-
gles are reached.
LS7632
- When a LONG touch is applied, the dimming stops when-
ever maximum or minimum conduction angles are reached. In order to
change dimming levels from maximum or minimum, LONG touch must
be removed and reapplied.The purpose of this feature is to allow the
user to positively locate maximum and minimum conduction angles.
TABLE 1
MODE SHORT TOUCH LONG TOUCH DIMMING
REVERSAL
PRE-TOUCH POST-TOUCH PRE-TOUCH POST-TOUCH
OFF
MAX(Note 1)
OFF/MIN
0
ON
OFF
MAX
INTERMEDIATE
(Note 5)
Varies up from MIN
Varies down from MAX
Varies from INTERMEDIATE
N/A
N/A
NO
OFF
MEMORY
(Notes 2, 3)
OFF
OFF
MIN
MAX
INTERMEDIATE
Varies from memory (Notes 2, 3,4)
Varies up from MIN
Varies down from MAX
Varies from INTERMEDIATE
YES
N/A
N/A
YES
1
ON
OFF
2
ON
MAX (Note 1)
OFF
OFF/MIN
MAX
INTERMEDIATE
Varies up from MIN
Varies down from MAX
Varies from INTERMEDIATE
N/A
N/A
YES
Note 1
:
A soft turn-on is produced by slewing up the conduction angle, , from minimum at the rate of 1.4
/4.17ms (60Hz).
There are a total of 84 discrete values of .
Note 2
: A soft turn-on is produced by slewing up , from minimum to memory.
Upon power-up the memory value is defaulted to maximum conduction angle.
Note 3
:
“Memory” refers to the conduction angle, , which existed prior to the current off-state.
Note 4
: A soft turn-on is produced by slewing up from minimum to memory upon which the dimming is started.
Note 5: NO
= Dimming direction does not reverse from prior dimming direction.
YES
= Dimming direction does reverse from prior dimming direction.
N/A
= Does not apply.
7631/7632-111902-2
LS7632 NOTE
: If the User applies a LONG Touch when
the TRIG Conduction Angle is within a “few” degrees of
Maximum or Minimum, the TRIG Conduction Angle can
move to Maximum or Minimum and stop without the User
being able to observe a change in brightness. Therefore,
the User should be instructed that if no change in bright-
ness is observed in response to a LONG Touch, the
LONG Touch should be removed and reapplied in order
to produce a change in brightness.
ABSOLUTE MAXIMUM RATINGS:
PARAMETER
SYMBOL
VALUE
UNIT
DC supply voltage
Any input voltage
Operating temperature
Storage temperature
V
DD
- Vss
V
IN
T
A
T
STG
+7
V
V
°C
°C
Vss - 0.3 to V
DD
+ 0.3
0 to +90
-65 to +150
DC ELECTRICAL CHARACTERISTICS:
(TA = +25C, all voltages referenced to Vss. V
DD
= +5V unless otherwise noted.)
PARAMETER
SYMBOL
MIN
TYP
MAX
UNIT
CONDITION
Supply voltage
Supply current
V
DD
I
DD
4.5
-
5.0
300
5.5
400
V
-
μA
Output unloaded
V
DD
= 5.5V
-
SYNC
Lo
V
ISL
-
-
2.1
V
SYNC
Hi
V
ISH
2.9
-
-
V
-
EXT, SENS
Lo
V
IEL
-
-
1.5
V
-
EXT, SENS
H
i
TRIG Lo
TRIG H
i
V
IEH
V
OL
V
OH
3.5
-
-
-
-
-
-
V
V
V
-
-
-
0.2
5.0
TRIG
Sink Current
I
TSNK
35
-
- mA
V
OTRIG
= 2.5V