Cassette Style
100 Watt AC-DC Converters
S Series PFC
Edition 01/01.2001
6/27
Electrical Output Data
General Conditions
–
TA = 25
°C, unless T
C is specied.
– Pin 18 (i) connected to pin 14 (S–/Vo1–),
Uo adjusted to Uo nom (option P), R input not connected.
– Sense line pins 12 (S+) and 14 (S–) connected to pins 4 (Vo1+) and 8 (Vo1–) respectively.
Table 4a: Output data single output modules
Output
LS 4001
LS 4301
LS 4501
LS 4601
5.1 V
12.0 V
15.0 V
24.0 V
Characteristics
Conditions
min
typ
max
min
typ
max
min
typ
max
min
typ
max
Unit
Uo
Output voltage
Ui nom, Io nom
5.07
5.13
11.93
12.07 14.91
15.09 23.86
24.14
Uop
Overvoltage protection
7.6
21
26.5
43.5
(supressor diode)
Io nom
Output current 1
Ui min...Ui max
16.0
8.0
6.5
4.2
A
TC min...TC max
IoL
Output current limit 2
Ui min...Ui max
16.2
8.2
6.7
4.4
uo 5
Output
Low frequency
Ui nom, Io nom
22
2
mVpp
voltage
Switching freq.
IEC/EN 61204
15
5
noise
Total
BW = 20 MHz
50
40
DUo U Static line regulation
Ui min...Ui nom,
±5
±12
±15
±24 mV
Ui nom...Ui max,
Io nom
DUo I
Static load regulation
Ui nom, Io =
202430
48
(0.1...1)
Io nom
uo d 3
Dynamic Voltage
Ui nom, Io =
±170
±150
±100
load
deviation
Io nom 1/2 Io nom
t d 3
regulat.
Recovery time
IEC/EN 61204
0.3
0.4
0.3
ms
aUo
Temperature coefficient
Ui min...Ui max
–0.5
-1.5
1.5
mV/K
of output voltage 4
0...
Io nom
1 If the output voltages are increased above Uo nom through R-input control, option P setting, remote sensing or option T, the output cur-
rents should be reduced accordingly so that
Po nom is not exceeded.
2 See: Output Voltage Regulation of Single or Double Output Modules with Outputs 1 and 2 Connected in Series.
3 See: Typical dynamic load regulation of Uo1 and Uo2.
4 Negative temperature coefcient (0...–3 mV/cell and K) available on request.
5 Measured according to IEC/EN 61204 sub clause 3.10 with a probe acc. to annex A of the same standards. (See:Technical Informa-
tion: Measuring and Testing)