■ RELIABILITY DATA
*This catalog contains the typical specication only due to the limitation of space. When you consider the purchase of our products, please check our specication.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs.
25. Loading under damp heat
LA Type
△L/L : Within ±10% Q : 30min
CAL45 Type
△L/L : Within ±10%
LHL□□□
Appearance : No abnormality
Imductance change : Within ±10%
Q change : Within ±30% (LHLP : only △L/L)
FBA/FBR
FL05□ Type
Refer to individual specication
FL06BT Type
Appearance : No abnormality
Impedance change : Within ±20%
【Test Method and Remarks】
LA, CA
: Temperature
: 40±2℃
Humidity
: 90~95%RH
Duration
: 1000 hrs
Applied current : Rated current
Recovery
: At least 1hr of recovery under the standard removal from test chamber, followed by the measurement within 2hrs.
LHL□□□ : Temperature
: 40±2℃
Humidity
: 90~95%RH
Duration
: 1000±24 hrs
Applied current : Rated current
Recovery
: 1 to 2hrs of recovery under the standard condition after the removal from the test chamber.
FL
: Temperature
: 60±3℃
Humidity
: 90~95%RH
Duration
: 500 (+12, ー0) hrs
Applied current : Rated current
Recovery
: 1 to 2hrs of recovery under the standard condition after the removal from the test chamber.
26. Loading at high temperature
LA Type
△L/L : Within ±10% Q : 30min
CAL45 Type
△L/L : Within ±10%
LHL□□□
FBA/FBR
FL05□ Type
FL06BT Type
【Test Method and Remarks】
LA, CA
: Temperature
: 85±2℃
Duration
: 1000 hrs
Applied current : Rated current
Recovery
: At least 1hr of recovery under the standard removal from test chamber, followed by the measurement within 2hrs.
27. Low temperature life test
LA Type
△L/L : Within ±10% Q : 30min
CAL45 Type
△L/L : Within ±10%
LHL□□□
Appearance : No abnormality
Inductance change : Within ±10%
Q change : Within ±30% (LHLP : only △L/L)
FBA/FBR
FL05□ Type
Refer to individual specication
FL06BT Type
Appearance : No abnormality
Impedance change : Within ±20%
【Test Method and Remarks】
LA, CA
: Temperature : ー25±2℃
Duration
: 1000 hrs
Recovery
: At least 1hr of recovery under the standard removal from test chamber, followed by the measurement within 2hrs.
LHL□□□ : Temperature : ー40±3℃
Duration
: 1000±24 hrs
Recovery
: 1 to 2hrs of recovery under the standard condition after the removal from the test chamber.
FL
: Temperature : ー40±3℃
Duration
: 500 (+12, ー0) hrs
Recovery
: 1 to 2hrs of recovery under the standard condition after the removal from the test chamber.
28. High temperature life test
LA Type
CAL45 Type
LHL□□□
Appearance : No abnormality
Inductance change : Within ±10%
Q change : Within ±30% (LHLP : only △L/L)
FBA/FBR
FL05□ Type
Refer to individual specication
FL06BT Type
Appearance : No abnormality
Impedance change : Within ±20%
【Test Method and Remarks】
LHL□□□ : Temperature : 105±3℃
Duration
: 1000±24 hrs
Recovery
: 1 to 2hrs of recovery under the standard condition after the removal from the test chamber.
FL
: Temperature : 85±3℃
Duration
: 500 (+12, ー0) hrs
Recovery
: 1 to 2hrs of recovery under the standard condition after the removal from the test chamber.