EUROPE
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44(1384) 843-355
AMERICAS
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
97
www.astec.com
Ordering Information
ASIA
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Fwai Fong, New Territories
Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
Model
Number
Output
Voltage
Minimum
Load
Maximum Load with
Convection Cooling
Maximum Load with
30 CFM Forced Air
Peak
Load1
Regulation2
Ripple
P/P (PARD)3
LPT61
+3.3 V
+5 V
+12 V
0.7A
0 A
0 A
5 A
2.5 A
0.5 A
8.5 A
3.0 A
1.0 A
9.5 A
3.3 A
1 A
±2%
±2%
±5%
50mV
50mV
120mV
LPT62
+5 V
+12 V
-12 V
0.7 A
0.3 A
0 A
7 A
3 A
0.7 A
8 A
3.5 A
1 A
10 A
6 A
1.5 A
±2%
±5%
±5%
50 mV
120 mV
120 mV
LPT63
+5 V
+15 V
-15 V
0.7 A
0.3 A
0 A
7 A
2.8 A
0.7 A
8 A
3.3 A
1 A
10 A
4 A
1.5 A
±2%
±5%
±5%
50 mV
150 mV
150 mV
LPT64
+5 V
+12 V
-5 V
0.7 A
0.3 A
0 A
7 A
3 A
0.7 A
8 A
3.5 A
1 A
10 A
6 A
1.5 A
±2%
±5%
±5%
50 mV
120 mV
50 mV
LPT65
+5 V
+24 V
+12 V
0.7 A
0.1 A
0 A
7 A
1.5 A
0.7 A
8 A
2.0 A
1 A
10 A
3 A
1.5 A
±2%
±7%
±5%
50 mV
240 mV
120 mV
LPT66
+5 V
+24 V
-12 V
0.7 A
0.1 A
0 A
7 A
1.5 A
0.7 A
8 A
2.0 A
1 A
10 A
3 A
1.5 A
±2%
±7%
±5%
50 mV
240 mV
120 mV
LPT67
+5 V
+24 V
-5 V
0.7 A
0.1 A
0 A
7 A
1.5 A
0.7 A
8 A
2.0 A
1 A
10 A
3 A
1.5 A
±2%
± 7%
± 5%
50 mV
240 mV
50 mV
1. Peak current lasting <30 seconds with a maximum 10% duty cycle.
2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 μF in parallel with a 0.1 μF capacitor at rated line voltage and load ranges.
4. Minimum Loads are required.
Mating Connectors
AC Input:
Molex 09-50-8031 (USA)
09-91-0300 (UK)
PINS: 08-58-0111
Molex 09-50-8061 (USA)
09-91-0600 (UK)
PINS: 08-58-0111
DC Outputs:
Remote Sense: Molex 22-01-2025
PINS: 08-50-0114
Astec Connector Kit #70-841-006,
includes all of the above.
Connector
LPT61
LPT62
LPT63
LPT64
LPT65
LPT66
LPT67
SK1-1
SK1-3
Neutral
Line
Neutral
Line
Neutral
Line
Neutral
Line
Neutral
Line
Neutral
Line
Neutral
Line
SK2-1
SK2-2
SK2-3
SK2-4
SK2-5
SK2-6
SK201-1
SK201-2
5 V
3.3 V
3.3 V
Common Common Common Common
Common Common Common Common
+12V
-12 V
+Sense
+Sense
-Sense
-Sense
+12 V
+5 V
+5 V
+15 V
+5 V
+5 V
+12 V
+5 V
+5 V
+24V
+5 V
+5 V
Common Common
Common Common
+12 V
+Sense
-Sense
+24V
+5 V
+5 V
+24V
+5 V
+5 V
Common
Common
-5 V
+Sense
-Sense
-15 V
+Sense
-Sense
-5 V
+Sense
-Sense
-12 V
+Sense
-Sense
Pin Assignments
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±.02”.
3. Mounting holes M1 and M2 should be grounded for
EMI purposes.
4. Mounting hole M1 is safety ground connection.
5. Specifications are for convection rating at factory
settings at 115 VAC input, 25°C unless otherwise stated.
6. Warranty: 1 year
7. Weight: 0.75 lb. / 0.34 kg
3.00"
(76.2)
2.55"
(64.8)
0.22"
(5.6)
1.65"
(41.9)
0.12"
(3)
4.55"
(115.6)
5.00"
(127)
SK 1
SK 2
1
2
3
4
5
6
0.15" (4)
DIA (4 places)
GND
1
3
N
L
M1
M2
_
Remote Sense
Connector
Voltage
Adj. Pot
SK201
Power Derating Curve
Output
Power
(Watts)
0
°
C
20W
40W
60W
80W
10
°
C 20
°
C 30
°
C 40
°
C 50
°
C 60
°
C 70
°
C
TA – Ambient Temperature –
°
C
0W
Natural
Convection
Cooling
40W
30W
30 CFM Forced Air Cooling
L