DIN-Rail Mountable
AC-DC Converters
O Series
Edition 3/4.2000
1/7
15, 30 Watt AC-DC Converters
Convert Simply 15, 30
Universal input range 85...264 V AC
Single output 24 V DC
3 kV AC I/O electric strength test voltage
Class II equipment (double insulation)
High efficiency up to 86%
Short circuit protection
High level of electromagnetic compatibility
Safety according to IEC/EN 60950
Table of Contents
Page
Summary .......................................................................... 1
Type Survey and Key Data .............................................. 1
Type Key and Product Marking ........................................ 2
Functional Description ...................................................... 2
Electrical Input Data ......................................................... 2
Electrical Output Data ...................................................... 3
Type Survey and Key Data
Table 1: Type survey
Output 1
Rated power
Input voltage
Efficiency 1
Type designation
Uo nom
TA = 50°C
Po nom
range
[V DC]
Io nom [mA]
[W]
Ui min…Ui max
htyp [%]
24
630
15
85...264 V AC
83
LOS 1601-2
24
1250
30
47...63 Hz
82
LOR 1601-2
110...330 V DC
1 Efficiency at Ui rated and Io nom.
Summary
The Convert Simply 15 and Convert Simply 30 front end
modules represent a series of 15 and 30 Watt DIN-rail
mountable AC-DC converters. Fully encapsulated case,
compact size and high reliability make the O series an ex-
cellent choice when a DIN-Rail mountable AC-DC con-
verter in space critical applications is required. The univer-
sal input range and a built-in input Pi-Filter allows flexible
operation in a wide variety of electronic equipment. Fine
output voltage trimming is achieved by an additional trim
pin. Safety approvals and EMC fully comply with world wide
requirements.
Key applications
Typical applications include, but are not limited to factory
automation, off-site test and measurement, and communi-
cations equipment.
LGA
Page
Auxiliary Functions ........................................................... 4
Electromagnetic Compatibility (EMC) .............................. 4
Immunity to Environmental Conditions ............................. 5
Mechanical Data .............................................................. 6
Safety and Installation Instructions .................................. 6
114.5
4.51"
110
4.33"
22.5
0.89"
114.5
4.51"
110
4.33"
35
1.38"
LOS
LOR