![](http://datasheet.mmic.net.cn/220000/LND317_datasheet_15486542/LND317_3.png)
LND317
Over recommended ranges of operating virtual junction temperature (unless otherwise noted) (see Note 1)
LM317
TYP
PARAMETER
TEST CONDITIONS
MIN
MAX
UNIT
T
J
=MIN to
MAX
0.01
0.04
Input regulation( See Note 2)
V
I
-V
O
= 3V to 40V,
(See Note 3)
I
O
=10mA to
1.5A
0.02
0.07
% / V
V
O
=10 V, f=120 Hz
V
O
=10 V, f=120 Hz
10-μF capacitor between ADJ and
ground
I
O
=10mA to 1.5 A,
T
J
=25oC,(See Note3)
65
Ripple rejection
66
80
dB
V
O
≤
5V
V
O
> 5V
V
O
≤
5V
5
25
0.5
70
mV
%
mV
0.1
20
Output Regulation
I
O
=10mA to 1.5A,
(see note 3)
V
O
>
5V
0.3
1.5
%
Output Voltage Change with
temperature
Output voltage long-term
drift(see note 4)
Output noise voltage
Minimum output current to
maintain regulation
T
J
=MIN to MAX
1
%
After 1000h at T
J
=MAX and
V
I
-V
O
=40V
f = 10Hz to 10kHz, T
J=
25oC
0.3
1
%
0.003
%
V
I
-V
O =
40V
3.5
10
mA
V
I -
V
O
≤
15V
V
I -
V
O
≤
40V, T
J
=25oC
1.5
0.15
2.2
0.4
50
Peak output current
A
Adjustment terminal current
Change in adjustment-
terminal current
Reference voltage(output to
ADJ)
100
μA
V
I
-V
O
=2.5V to 40V,
I
O
=10mA to 1.5A
V
I -
V
O =
3V to 40V, I
O
=10mA to 1.5A,
P
≤
15W
0.2
5.0
μA
1.2
1.25
1.3
V
Unless otherwise noted, these specifications apply for the following test conditions: V
V
5V and I
O=
0.5A. For conditions shown as
MIN or MAX, use the appropriate value specified under recommended operating conditions.
Notes:
1.
2.
3.
All characteristics are measured with a 0.1-μF capacitor across the input and a 1-
μ
F capacitor across the output.
Input regulation is expressed here as the percentage change in output voltage per 1-V change at the input.
Pulse testing techniques are used to maintain the junction temperature as close to the ambient temperature as possible.
Thermal effects must be taken into account separately.
Since long-term drift cannot be measured on the individual devices prior to shipment, this specification is not intended to be a
guarantee or warranty. It is an engineering estimate of the average drift to be expected from lot to lot.
4.
ELECTRICAL CHARACTERISTICS
Linear Dimensions, Inc.
445 East Ohio Street, Chicago IL 60611 USA
tel 312.321.1810
fax 312.321.1830
www.lineardimensions.com