![](http://datasheet.mmic.net.cn/230000/LM60_datasheet_15593168/LM60_3.png)
Absolute Maximum Ratings
(Note 1)
Supply Voltage
Output Voltage
+12V to 0.2V
(+V
S
+ 0.6V) to
0.6V
10 mA
5 mA
Output Current
Input Current at any pin (Note 2)
ESD Susceptibility (Note 3) :
Human Body Model
Machine Model
SOT-23
TO-92
Recommended Lead Temperature
(Note 4):
SOT Package:
Vapor Phase (60 sec)
Infrared (15 sec)
TO-92 Package (3 sec, dwell time)
2500V
250V
200V
+215C
+220C
+240C
Storage Temperature
65C to
+150C
Maximum Junction Temperature
(T
JMAX
)
+125C
Operating Ratings
(Note 1)
Specified Temperature Range:
LM60B
LM60C
Supply Voltage Range (+V
S
)
Thermal Resistance,
θ
JA
(Note
5)
SOT-23
TO-92
T
MIN
≤
T
A
≤
T
MAX
25C
≤
T
A
≤
+125C
40C
≤
T
A
≤
+125C
+2.7V to +10V
450C/W
180C/W
Electrical Characteristics
Unless otherwise noted, these specifications apply for +V
S
= +3.0 V
DC
and I
LOAD
= 1 μA.
Boldface limits apply for T
A
= T
J
= T
MIN
to T
MAX
; all other limits T
A
= T
J
= 25C.
Parameter
Conditions
Typical
(Note 6)
LM60B
Limits
(Note 7)
±
2.0
±
3.0
LM60C
Limits
(Note 7)
±
3.0
±
4.0
Units
(Limit)
Accuracy (Note 8)
C (max)
C (max)
mV
C (max)
mV/C (min)
mV/C (max)
(max)
mV/V (max)
mV (max)
μA (max)
μA (max)
μA (max)
μA/C
Output Voltage at 0C
Nonlinearity (Note 9)
Sensor Gain
(Average Slope)
Output Impedance
Line Regulation (Note 10)
+424
±
0.6
+6.06
+6.44
800
±
0.3
±
2.3
110
125
±
0.8
+6.00
+6.50
800
±
0.3
±
2.3
110
125
+6.25
+3.0V
≤
+V
S
≤
+10V
+2.7V
≤
+V
S
≤
+3.3V
+2.7V
≤
+V
S
≤
+10V
Quiescent Current
82
Change of Quiescent Current
Temperature Coefficient of
Quiescent Current
Long Term Stability (Note 11)
+2.7V
≤
+V
S
≤
+10V
±
5.0
0.2
T
J
=T
MAX
=+125C, for
1000 hours
±
0.2
C
Note 1:
Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for which the device is
functional, but do not guarantee specific performance limits. For guaranteed specifications and test conditions, see the Electrical Characteristics. The guaranteed
specifications apply only for the test conditions listed. Some performance characteristics may degrade when the device is not operated under the listed test
conditions.
Note 2:
When the input voltage (V
I
) at any pin exceeds power supplies (V
I
<
GND or V
I
>
+V
S
), the current at that pin should be limited to 5 mA.
Note 3:
The human body model is a 100 pF capacitor discharged through a 1.5 k
resistor into each pin. The machine model is a 200 pF capacitor discharged
directly into each pin.
Note 4:
See the URL ”http://www.national.com/packaging/“ for other recomdations and methods of soldering surface mount devices.
Note 5:
The junction to ambient thermal resistance (
θ
JA
) is specified without a heat sink in still air.
Note 6:
Typicals are at T
J
= T
A
= 25C and represent most likely parametric norm.
Note 7:
Limits are guaranteed to National’s AOQL (Average Outgoing Quality Level).
Note 8:
Accuracy is defined as the error between the output voltage and +6.25 mV/C times the device’s case temperature plus 424 mV, at specified conditions of
voltage, current, and temperature (expressed in C).
Note 9:
Nonlinearity is defined as the deviation of the output-voltage-versus-temperature curve from the best-fit straight line, over the device’s rated temperature
range.
L
www.national.com
3