    Isolation
    The electric strength test is performed as a factory test in
    accordance with IEC/EN 60950 and UL 1950 and should
    not be repeated in the field. Power-One will not honour any
    Table 15: Isolation
    Characteristic
    Input to
    Output to Output to Output to
    Unit
    case
    output
    case
    output
    class I
    class II
    class I
    class II
    option H
    Electric
    Required according to
    1.5
    3.0
    3.0 1
    3.0
    0.5
    -
    kVrms
    strength
    IEC/EN 60950
    2.1
    4.2
    4.2 1
    4.2
    0.7
    -
    kV DC
    test voltage
    Actual factory test 1 s
    2.8
    5.6
    5.6 1
    5.6
    1.4
    2.8
    0.3
    AC test voltage equivalent
    2.0
    4.0
    4.0 1
    4.0
    1.0
    2.0
    0.2
    kVrms
    to actual factory test
    Insulation resistance at 500 V DC
    >300
    >100 2
    M
    1 In accordance with IEC/EN 60950 only subassemblies are tested in factory with this voltage.
    2 Tested at 300 V DC.
    For creepage distances and clearances refer to:
    Technical Information: Safety.
    Safety of Operator Accessible Output Circuit
    If the output circuit of a DC-DC converter is operator acces-
    sible, it shall be an SELV circuit according to the IEC/EN
    60950 related safety standards.
    Since the M series DC-DC converters provide double or re-
    inforced insulation between input and output, based on a
    rated primary input voltage of 250 V AC and 400 V DC (for
    class II units 250 V AC and DC), only operational insulation
    is needed between the AC mains and the input of the DC-
    DC converter. This means that there is no need for an elec-
    trical isolation between the AC mains circuit and the DC-DC
    converter input circuit to cause the output of an M series
    DC-DC converter to be an SELV circuit. Only voltage
    adaption and rectification to the specified input voltage
    range of the DC-DC converter is needed.
    The following table shows a possible installation configura-
    tion, compliance with which causes the output circuit of the
    DC-DC converter to be an SELV circuit according to IEC/
    EN 60950 up to a configured output voltage (sum of nomi-
    nal voltages if in series or +/– configuration) of 36 V.
    However, it is the sole responsibility of the installer to as-
    sure the compliance with the relevant and applicable safety
    regulations. More information is given in:
    Technical Infor-
    mation: Safety.
    Table 16: Safety concept leading to an SELV output circuit
    Conditions
    Front end
    DC-DC converter
    Result
    Nominal
    Minimum required grade
    Maximum rated
    Minimum required
    Equip-
    Measures to achieve the
    Safety status
    supply
    of insulation, to be pro-
    DC output voltage
    safety status of the
    ment
    specified safety status of
    of the DC-DC
    voltage
    vided by the AC-DC front
    from the front end
    front end output
    the output circuit
    converter
    end, including mains
    circuit
    output circuit
    supplied battery charger
    Mains
    Operational (i.e. there is
    ≤400 V 1 (The
    Primary circuit
    Class I
    Double or reinforced
    SELV circuit
    ≤250 V AC no need for electrical
    rated voltage
    (A...LM) insulation, based on
    isolation between the
    between any input
    250 V AC and 400 V DC
    mains supply voltage and
    pin and earth can
    (provided by the DC-DC
    theDC-DC converter
    be up to 250 V AC
    converter) and earthed
    input voltage)
    or 400 V DC)
    case 2
    ≤250 V 1 (The
    Class II
    Double or reinforced
    rated voltage
    (CMZ,
    insulation, based on
    between any input
    DMZ,
    250 V AC or DC (provided
    pin and earth can
    LMZ)
    by the DC-DC converter)
    be up to 250 V AC
    or DC)
    1 The front end output voltage should match the specified operating input voltage range of the DC-DC converter.
    2 The earth connection has to be provided by the installer according to the relevant safety standard, e.g. IEC/EN 60950.
    guarantee/warranty claims resulting from electric strength
    field tests.
    相關(guān)PDF資料
    PDF描述
    LM3040-7EPD6AH 3-OUTPUT 50 W AC-DC REG PWR SUPPLY MODULE
    LM3040-7EPD6HF 3-OUTPUT 50 W AC-DC REG PWR SUPPLY MODULE
    LM3040-7PD2AH 3-OUTPUT 50 W AC-DC REG PWR SUPPLY MODULE
    LM3040-9EPD4H 3-OUTPUT 50 W AC-DC REG PWR SUPPLY MODULE
    LM3040-9EPD9H 3-OUTPUT 50 W AC-DC REG PWR SUPPLY MODULE
    相關(guān)代理商/技術(shù)參數(shù)
    參數(shù)描述
    LM3040-7F 制造商:POWER-ONE INC 功能描述:DC/DC CONVERTER; EURO-CASSETTE 50W 5.1V + 2X 15V
    LM3040-9 制造商:Power-One 功能描述:ACDC - Bulk
    LM3045 制造商:NSC 制造商全稱:National Semiconductor 功能描述:LM3045/LM3046/LM3086 Transistor Arrays
    LM3045 WAF 制造商:Texas Instruments 功能描述:
    LM3045J 制造商:Texas Instruments 功能描述: