LM124, LM124A, LM224, LM224A
LM324, LM324A, LM324Y, LM2902, LM2902Q
QUADRUPLE OPERATIONAL AMPLIFIERS
SLOS066E– SEPTEMBER 1975 – REVISED FEBRUARY1997
3–4
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
LM124, LM124A
LM224, LM224A
LM324, LM324A
LM2902,
LM2902Q
UNIT
Supply voltage, VCC (see Note 1)
Differential input voltage, VID (see Note 2)
Input voltage, VI (either input)
Duration of output short circuit (one amplifier) to ground at (or below) TA = 25
°
C,
VCC
≤
15 V (see Note 3)
Continuous total dissipation
32
±
32
26
±
26
V
V
–0.3 to 32
–0.3 to 26
V
unlimited
unlimited
See Dissipation Rating Table
LM124, LM124A
–55 to 125
Operating free air temperature range TA
Operating free-air temperature range, TA
LM224, LM224A
–25 to 85
°
C
LM324, LM324A
0 to 70
LM2902, LM2902Q
–40 to 125
Storage temperature range
–65 to 150
–65 to 150
°
C
°
C
°
C
°
C
Case temperature for 60 seconds
FK package
260
Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds
J or W package
300
300
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES:
1. All voltage values (except differential voltages and VCC specified for the measurement of IOS) are with respect to the network GND.
2. Differential voltages are at IN + with respect to IN –.
3. Short circuits from outputs to VCC can cause excessive heating and eventual destruction.
D, DB, N, or PW package
260
260
DISSIPATION RATING TABLE
PACKAGE
TA
≤
25
°
C
POWER RATING
DERATING
FACTOR
DERATE
ABOVE TA
32
°
C
25
°
C
68
°
C
68
°
C
40
°
C
52
°
C
25
°
C
37
°
C
TA = 70
°
C
POWER RATING
TA = 85
°
C
POWER RATING
TA = 125
°
C
POWER RATING
D
900 mW
7.6 mW/
°
C
6.2 mW/
°
C
11.0 mW/
°
C
11.0 mW/
°
C
8.2 mW/
°
C
9.2 mW/
°
C
5.6 mW/
°
C
8.0 mW/
°
C
611 mW
497 mW
N/A
DB
775 mW
496 mW
403 mW
N/A
FK
900 mW
878 mW
713 mW
273 mW
J (LM124_)
900 mW
878 mW
713 mW
273 mW
J (all others)
900 mW
654 mW
531 mW
N/A
N
900 mW
734 mW
596 mW
N/A
PW
700 mW
448 mW
364 mW
N/A
W
900 mW
636 mW
516 mW
196 mW