參數(shù)資料
型號: LK2660-9PD8TB1
元件分類: 電源模塊
英文描述: 2-OUTPUT 150 W AC-DC REG PWR SUPPLY MODULE
封裝: METAL, CASE K02, MODULE
文件頁數(shù): 27/27頁
文件大?。?/td> 640K
代理商: LK2660-9PD8TB1
K-Family
DC-DC Converters >100 W
Rugged Environment
8 - 10
Edition 2/96 - Melcher AG
MELCHER
The Power Partners.
8.1
Immunity
Table 6: Immunity type tests
Phenomenon
Standard
Level
Value
applied
Waveform
Source
impedance
Test
procedure
In
operation
Performance
Coupling
mode
4
Voltage surge
IEC 571-1 3
i/c, +i/–i
800 Vp
100
s
100
1 pos. and 1 neg.
yes
1
(1990-07)
1500 Vp
50
s
voltage surge per
3000 Vp
5
s
coupling mode
4000 Vp
1
s
7000 Vp
100 ns
Supply related
RIA 12
A 5
+i/–i
3.5
Ubatt
20 ms
0.2
1 positive
yes
1
surge
(1984)
B
1.5
U
batt
1 s
surge
Direct transient
C
+i/c, –i/c
960 Vp
10/100
s5
5 pos. and 5 neg.
2
D
1800 Vp
5/50
s
impulses
E
3600 Vp
0.5/5
s
100
F
4800 Vp
0.1/1
s
G
8400 Vp
0.05/0.1
s
Indirect coupled
H
+o/c, –o/c
1800 Vp
5/50
s
6
transient
J
3600 Vp
0.5/5
s
K
4800 Vp
0.1/1
s
L
8400 Vp
0.05/0.1
s
Electrostatic
IEC 801-2
4
contact discharge
8000 Vp
1/50 ns
330
10 positive and
yes
1
discharge
(1991-04)
to case,
10 negative
air disch. to case
15000 Vp
discharges
Electric field
IEC 801-3
3
antenna in
10 V/m
AM modulated
26…1000 MHz
yes
1
(1984)
1 m distance
80 % 1 kHz
ENV 50204
unmodulated
900
± 5 MHz
50% duty cycle
Fast transient /
IEC 801-4
3
i/c, +i/–i
2000 Vp bursts of 5/50 ns
50
1 min positive
yes
1
burst
(1988)
5 kHz rep. rate
1 min negative
transients with
bursts per
15 ms burst
coupling mode
duration and a
4
4000 Vp
300 ms period
Transient
IEC 801-5
3
i/c
2000 Vp
1.2/50
s
12
yes
1
(Draft 1993-01)
4
+i/–i
2000 Vp
2
impulses per
coupling mode
Conducted
IEC 801-6
3
i, o, signal wires 140 dB
V
AM modulated
150
0.15...80 MHz
yes
1
disturbance
(Draft1992-12)
(10 Vrms)
80%, 1 kHz
1 Normal operation, no deviation from specifications.
2 Normal operation, temporary deviation from specifications possible.
3 Will be replaced by EN 50155.
4 i = input, o = output, c = case
5 Only met with extended input voltage range of CK (48 V battery) and EK (110 V battery) types. These units are available upon cus-
tomer's request. Standard DK units (110 V battery) will not be damaged, but overvoltage lock-out will occur during the surge.
Under normal operation temporary deviation from specifications possible.
6 Test in progress, please consult factory.
相關(guān)PDF資料
PDF描述
LK1001-9ERD2T 1-OUTPUT 150 W AC-DC REG PWR SUPPLY MODULE
LK1001-9ERD5 1-OUTPUT 150 W AC-DC REG PWR SUPPLY MODULE
LK1301-9ERD9T 1-OUTPUT 150 W AC-DC REG PWR SUPPLY MODULE
LK1501-9EPD6T 1-OUTPUT 150 W AC-DC REG PWR SUPPLY MODULE
LK1501-9ERD5B1 1-OUTPUT 150 W AC-DC REG PWR SUPPLY MODULE
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
LK28 制造商:Molex 功能描述:BOX, LINE FEED 4D/PRF
LK28-LAS-F1-Z/31/116 制造商:PEPPERL+FUCHS 功能描述:SENSOR, PHOTOELECTRIC, UNIVERSAL STYLE, THRU-BEAM RECEIVER, SENSING DIS 300M 制造商:PEPPERL+FUCHS 功能描述:Photoelectric (Automation)
LK2A 制造商:HellermannTyton 功能描述:
LK2A-BLACK 制造商:HellermannTyton 功能描述:CABLE TIE HEAVYDUTY BLACK 270MM 制造商:HellermannTyton 功能描述:CABLE TIE, HEAVYDUTY, BLACK, 270MM 制造商:HELLERMANN TYTON 功能描述:CABLE TIE, HEAVYDUTY, BLACK, 270MM; Cable Tie Length:270mm; Cable Tie Width:4.6mm; Cable Tie Material:Nylon 6.6 (Polyamide 6.6); Cable Tie Colour:Black; Tensile Strength N/m2:225N/mm2; Cable Bundle Diameter Min:5mm; Cable Bundle ;RoHS Compliant: Yes
LK2A-BLACK 制造商:HellermannTyton 功能描述:CABLE TIE H/D BLK 270MM PK100