參數(shù)資料
型號(hào): LK2660-7EPD0TB2
廠商: POWER-ONE INC
元件分類: 電源模塊
英文描述: 2-OUTPUT 150 W AC-DC REG PWR SUPPLY MODULE
封裝: METAL, CASE K02, MODULE
文件頁(yè)數(shù): 11/26頁(yè)
文件大?。?/td> 1027K
代理商: LK2660-7EPD0TB2
Cassette Style
AC-DC Converters
K Series
Edition 5/5.2000
19/26
Leakage Currents in AC-DC operation
Leakage currents flow due to internal leakage capacitance
and RFI suppression Y-capacitors. The current values are
proportional to the mains voltage and nearly proportional to
the mains frequency and are specified at an input voltage of
264 V (50 Hz) where phase, neutral and protective earth
are correctly connected as required for class I equipment.
Under test conditions the leakage current flows through a
measuring instrument (MI) as described in fig.:
Measuring
instrument for earth leakage current tests, which takes into
account impedance and sensitivity of a person touching
unearthed accessible parts. The current value is calculated
by dividing the measured voltage by 500
. If inputs and/or
outputs of K-units are connected in parallel, their individual
leakage currents are added.
Fig. 25
Measuring instrument (MI) for earth leaking current tests
according to IEC/EN 60950.
Fig. 26
Test set-up
V
MI
500
1500
10 k
220 nF
22 nF
10061
Vo+
Vo–
N
P
10064
N
P
MI for
earth
leakage
current
Table 14: Leakage currents
Characteristic
Class I
Unit
LK 1000, LK 2000
Maximum earth
Permissible according to IEC/EN 60950
3.5
mA
leakage current
Specified value at 264 V, 50 Hz
1.43
Safety of operator accessible output circuit
If the output circuit of an AC-DC converter is operator ac-
cessible, it shall be an SELV circuit according to the IEC/EN
60950 related safety standards.
The following table shows a possible installation configura-
tion, compliance with which causes the output circuit of an
K series AC-DC converter to be an SELV circuit according
to IEC/EN 60950 up to a configured output voltage (sum of
nominal voltages if in series or +/– configuration) of 36 V.
However, it is the sole responsibility of the installer to as-
sure the compliance with the relevant and applicable safety
regulations. More information is given in
Technical Informa-
tion: Safety.
If the K series AC-DC converters are used as DC-DC con-
verters, please refer to the data sheet
DC-DC converters
>100 W: K series.
Table 15: Safety concept leading to an SELV output circuit
Conditions
AC-DC converter
Installation
Result
Nominal voltage
Grade of insulation
Measures to achieve the resulting
Safety status of the AC-DC
between input and output
safety status of the output circuit
converter output circuit
provided by the AC-DC converter
Mains
Double or reinforced
Earthed case 1 and installation
SELV circuit
≤250 V AC
according to the applicable standards
1 The earth connection has to be provided by the installer according to the relevant safety standards, e.g. IEC/EN 60950.
AC-DC
con-
verter
Mains
SELV
Earth connection
+
~
10021
Fuse
Fig. 27
Schematic safety concept. Use fuses and earth connec-
tion as per: Installation Instructions and table: Safety con-
cept leading to an SELV output circuit.
相關(guān)PDF資料
PDF描述
LK2660-7ERD2TB2 2-OUTPUT 150 W AC-DC REG PWR SUPPLY MODULE
LK2660-7ERDDTB2 2-OUTPUT 150 W AC-DC REG PWR SUPPLY MODULE
LK2660-7RD8TB1 2-OUTPUT 150 W AC-DC REG PWR SUPPLY MODULE
LK2660-9D9B2 2-OUTPUT 150 W AC-DC REG PWR SUPPLY MODULE
LK2660-9RD4T 2-OUTPUT 150 W AC-DC REG PWR SUPPLY MODULE
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
LK2660-7ERT 制造商:Power-One 功能描述:AC DC - Bulk
LK2660-7R 功能描述:線性和開關(guān)式電源 Euro-Cassette 150W (2x 24V) RoHS:否 制造商:TDK-Lambda 產(chǎn)品:Switching Supplies 開放式框架/封閉式:Enclosed 輸出功率額定值:800 W 輸入電壓:85 VAC to 265 VAC 輸出端數(shù)量:1 輸出電壓(通道 1):20 V 輸出電流(通道 1):40 A 商用/醫(yī)用: 輸出電壓(通道 2): 輸出電流(通道 2): 安裝風(fēng)格:Rack 長(zhǎng)度: 寬度: 高度:
LK2660-9ER 制造商:Power-One 功能描述:ACDC - Bulk
LK28 制造商:Molex 功能描述:BOX, LINE FEED 4D/PRF
LK28-LAS-F1-Z/31/116 制造商:PEPPERL+FUCHS 功能描述:SENSOR, PHOTOELECTRIC, UNIVERSAL STYLE, THRU-BEAM RECEIVER, SENSING DIS 300M 制造商:PEPPERL+FUCHS 功能描述:Photoelectric (Automation)