參數(shù)資料
型號(hào): LK1601-9RDDT
元件分類: 電源模塊
英文描述: 1-OUTPUT 150 W AC-DC REG PWR SUPPLY MODULE
封裝: HEAT SINK, METAL, CASE K02, MODULE
文件頁(yè)數(shù): 11/26頁(yè)
文件大?。?/td> 601K
代理商: LK1601-9RDDT
Cassette Style
150 Watt AC-DC Converters
K Series
Edition 01/01.2001
19/26
Leakage Currents in AC-DC operation
Leakage currents flow due to internal leakage capacitance
and RFI suppression Y-capacitors. The current values are
proportional to the mains voltage and nearly proportional to
the mains frequency and are specified at an input voltage of
264 V (50 Hz) where phase, neutral and protective earth
are correctly connected as required for class I equipment.
Under test conditions the leakage current flows through a
measuring instrument (MI) as described in fig.:
Measuring
instrument for earth leakage current tests, which takes into
account impedance and sensitivity of a person touching
unearthed accessible parts. The current value is calculated
by dividing the measured voltage by 500
. If inputs and/or
outputs of K-units are connected in parallel, their individual
leakage currents are added.
Fig. 25
Measuring instrument (MI) for earth leaking current tests
according to IEC/EN 60950.
Fig. 26
Test set-up
V
MI
500
1500
10 k
220 nF
22 nF
10061
Vo+
Vo–
N
P
10064
N
P
MI for
earth
leakage
current
Table 14: Leakage currents
Characteristic
Class I
Unit
LK 1000, LK 2000
Maximum earth
Permissible according to IEC/EN 60950
3.5
mA
leakage current
Specified value at 264 V, 50 Hz
1.43
Safety of operator accessible output circuit
If the output circuit of an AC-DC converter is operator ac-
cessible, it shall be an SELV circuit according to the IEC/EN
60950 related safety standards.
The following table shows a possible installation configura-
tion, compliance with which causes the output circuit of an
K series AC-DC converter to be an SELV circuit according
to IEC/EN 60950 up to a configured output voltage (sum of
nominal voltages if in series or +/– configuration) of 36 V.
However, it is the sole responsibility of the installer to as-
sure the compliance with the relevant and applicable safety
regulations. More information is given in
Technical Informa-
tion: Safety.
If the K series AC-DC converters are used as DC-DC con-
verters, please refer to the data sheet
DC-DC converters
>100 W: K series.
Table 15: Safety concept leading to an SELV output circuit
Conditions
AC-DC converter
Installation
Result
Nominal voltage
Grade of insulation
Measures to achieve the resulting
Safety status of the AC-DC
between input and output
safety status of the output circuit
converter output circuit
provided by the AC-DC converter
Mains
Double or reinforced
Earthed case 1 and installation
SELV circuit
≤250 V AC
according to the applicable standards
1 The earth connection has to be provided by the installer according to the relevant safety standards, e.g. IEC/EN 60950.
AC-DC
con-
verter
Mains
SELV
Earth connection
+
~
10021
Fuse
Fig. 27
Schematic safety concept. Use fuses and earth connec-
tion as per: Installation Instructions and table: Safety con-
cept leading to an SELV output circuit.
相關(guān)PDF資料
PDF描述
LK2320-7ERD8TB2 2-OUTPUT 150 W AC-DC REG PWR SUPPLY MODULE
LK2320-7PD1TB2 2-OUTPUT 150 W AC-DC REG PWR SUPPLY MODULE
LK2320-9ERD1B2 2-OUTPUT 150 W AC-DC REG PWR SUPPLY MODULE
LK2320-9ERDDTB1 2-OUTPUT 150 W AC-DC REG PWR SUPPLY MODULE
LK2320-9PD1TB2 2-OUTPUT 150 W AC-DC REG PWR SUPPLY MODULE
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
LK1608100K-T 功能描述:固定電感器 INDCTR STD MULTILYR 0603 10uH 10% RoHS:否 制造商:AVX 電感:10 uH 容差:20 % 最大直流電流:1 A 最大直流電阻:0.075 Ohms 工作溫度范圍:- 40 C to + 85 C 自諧振頻率:38 MHz Q 最小值:40 尺寸:4.45 mm W x 6.6 mm L x 2.92 mm H 屏蔽:Shielded 端接類型:SMD/SMT 封裝 / 箱體:6.6 mm x 4.45 mm
LK1608100K-T 制造商:TAIYO YUDEN 功能描述:Inductor Series:LF LK 制造商:TAIYO YUDEN 功能描述:MULTI-LAYER SMD INDUCTOR
LK-1608-100KTK 功能描述:固定電感器 10uH 5mA 10% Wound Chip RoHS:否 制造商:AVX 電感:10 uH 容差:20 % 最大直流電流:1 A 最大直流電阻:0.075 Ohms 工作溫度范圍:- 40 C to + 85 C 自諧振頻率:38 MHz Q 最小值:40 尺寸:4.45 mm W x 6.6 mm L x 2.92 mm H 屏蔽:Shielded 端接類型:SMD/SMT 封裝 / 箱體:6.6 mm x 4.45 mm
LK1608100M-T 功能描述:固定電感器 INDCTR STD MULTILYR 0603 10uH 20% RoHS:否 制造商:AVX 電感:10 uH 容差:20 % 最大直流電流:1 A 最大直流電阻:0.075 Ohms 工作溫度范圍:- 40 C to + 85 C 自諧振頻率:38 MHz Q 最小值:40 尺寸:4.45 mm W x 6.6 mm L x 2.92 mm H 屏蔽:Shielded 端接類型:SMD/SMT 封裝 / 箱體:6.6 mm x 4.45 mm
LK1608120K-T 功能描述:固定電感器 INDCTR STD MULTILYR 0603 12uH 10% RoHS:否 制造商:AVX 電感:10 uH 容差:20 % 最大直流電流:1 A 最大直流電阻:0.075 Ohms 工作溫度范圍:- 40 C to + 85 C 自諧振頻率:38 MHz Q 最小值:40 尺寸:4.45 mm W x 6.6 mm L x 2.92 mm H 屏蔽:Shielded 端接類型:SMD/SMT 封裝 / 箱體:6.6 mm x 4.45 mm