Cassette Style
150 Watt AC-DC Converters
K Series
Edition 01/01.2001
7/26
Table 4c: Output data double output modules
Output
LK 2320
LK 2540
(Outputs independently loaded)
12 V/12 V
15 V/15 V
Characteristics
Conditions
Output 1
Output 2
Output 1
Output 2
min
typ
max
min
typ
max
min
typ
max
min
typ
max
Unit
Uo
Output voltage
Ui nom, Io nom 2
11.93
12.07 11.82
12.18 14.91
15.09 14.78
15.22
V
Uop
Overvoltage protection
19
24
(supressor diode)
Io nom
Output current 3
Ui min...Ui max
6.0
5.0
A
TC min...TC max
IoL
Output current limit 4
Ui min...Ui max
6.2
5.2
uo 8
Output
Low frequency
Ui nom, Io nom
3333
mVpp
voltage
Switching freq.
IEC/EN 61204
3333
noise
Total
BW = 20 MHz
40
25
50
20
DUo U
Static line regulation
Ui min...Ui nom
±30
±40
±30
±40
mV
Ui nom...Ui max
Io nom
DUo I
Static load regulation
Ui nom, Io =
100
5
100
5
(0.1...1)
Io nom 5
uo d 6
Dynamic Voltage
Ui nom, Io =
±80
load
deviation
Io nom 1/2 Io nom
td 6
regulat.
Recovery time
IEC/EN 61204
0.2
ms
aUo
Temperature coefficient
Ui min...Ui max
–1.1
mV/K
of output voltage 7
0...
Io nom
Table 4d: Output data double output modules
Output
LK 2660
(Outputs independently loaded) 1
24 V/24 V
Characteristics
Conditions
Output 1
Output 2
min
typ
max
min
typ
max
Unit
Uo
Output voltage
Ui nom, Io nom 2
23.86
24.14 23.64
24.36
V
Uop
Overvoltage protection
37
(supressor diode)
Io nom
Output current 3
Ui min...Ui max
3.0
A
TC min...TC max
IoL
Output current limit 4
Ui min...Ui max
3.2
uo 8
Output
Low frequency
Ui nom, Io nom
33
mVpp
voltage
Switching freq.
IEC/EN 61204
33
noise
Total
BW = 20 MHz
50
20
DUo U
Static line regulation
Ui min...Ui nom,
±30
±50
mV
Ui nom...Ui max,
Io nom
DUo I
Static load regulation
Ui nom, Io =50
5
(0.1...1)
Io nom 5
uo d 6
Dynamic Voltage
Ui nom, Io =
±50
load
deviation
Io nom 1/2 Io nom
td 6
regulat.
Recovery time
IEC/EN 61204
0.2
ms
aUo
Temperature coefficient
Ui min...Ui max
-1.3
mV/K
of output voltage 7
0...
Io nom
1 Depending upon the desired output
configuration the wiring should be
made as shown in:
R-Function for
different output configurations.
2 Same conditions for both outputs.
3 If the control voltages are in-
creased above
Uo nom via R-input
control, option P setting, remote
sensing or option T, the output cur-
rents should be reduced accord-
ingly so that
Po nom is not ex-
ceeded.
4 See: Output voltage regulation of
single output units.
5 Condition for specified output.
Other output loaded with constant
current
Io = Io nom. See: Output volt-
age regulation of double output
modules with output 1 and 2 in
symmetrical configuration.
6 See: Typical dynamic load regula-
tion of Uo1 and Uo2.
7 Negative temperature coefficient
(0....–3 mV/cell and K) available on
request.
8 Measured according to IEC/EN
61204 sub clause 3.10 with a
probe acc. to annex A of the same
standards. (See:
Technical Infor-
mation: Measuring and Testing.)