Current Transducer LF 2005-S
For the electronic measurement of currents : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
Electrical data
I
PN
I
P
R
M
Primary nominal r.m.s. current
Primary current, measuring range @ ± 24 V
Measuring resistance
2000
0 .. ± 3000
R
M min
0
0
5
5
A
A
R
M max
8
5
29
11
with ± 15 V
@ ± 2000 A
max
@ ± 2200 A
max
@ ± 2000 A
max
@ ± 3000 A
max
with ± 24 V
I
SN
K
N
V
C
I
C
V
d
Secondary nominal r.m.s. current
Conversion ratio
Supply voltage (± 5 %)
Current consumption
R.m.s. voltage for AC isolation test, 50 Hz, 1 mn
400
1 : 5000
± 15 .. 24
33
(@ ± 24 V) +
I
S
mA
6
mA
V
kV
Accuracy - Dynamic performance data
X
G
e
L
Overall accuracy @
I
PN
,
T
A
= 25°C
Linearity
± 0.3
< 0.1
%
%
Typ
Max
± 0.5
± 0.4
I
O
I
OT
t
di/dt
f
Offset current @
I
P
= 0,
T
A
= 25°C
Thermal drift of
I
O
Response time
1)
@ 90 % of
I
PN
di/dt
accurately followed
Frequency bandwidth (- 1 dB)
mA
mA
- 25°C .. + 70°C
± 0.2
< 1
> 50
DC .. 100
μs
A/μs
kHz
General data
T
A
T
S
R
S
m
Ambient operating temperature
Ambient storage temperature
Secondary coil resistance @
T
A
= 70°C
Mass
Standards
2)
- 25 .. + 70
- 40 .. + 85
25
1.5
EN 50178
°C
°C
kg
Notes :
1)
With a di/dt of 100 A/μs
2)
A list of corresponding tests is available.
Features
Closed loop (compensated) current
transducer using the Hall effect
Insulated plastic case recognized
according to UL 94-V0.
Advantages
Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
Current overload capability.
Applications
AC variable speed drives and servo
motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS)
Power supplies for welding
applications.
I
PN
=
2000
A
020708/5
L E M Components
www.lem.com