LC863264/56/48/40A
No.6694-15/20
Recommended Oscillation Circuit and Sample Characteristics
The sample oscillation circuit characteristics in the table below is based on the following conditions:
Recommended circuit parameters are verified by an oscillator manufacturer using a Sanyo provided oscillation evaluation
board.
Sample characteristics are the result of the evaluation with the recommended circuit parameters connected externally.
Recommended oscillation circuit and sample characteristics (Ta = -10 to +70
°
C)
Recommended circuit
parameters
Oscillation
stabilizing
time
typ.
1.00s
Notes
Frequency
Manufacturer
Oscillator
C1
18pF
C2
18pF
Rf
Open 390k
Rd
Operating
supply voltage
range
max
1.50s
32.768kHz
The oscillation stabilizing time period is the time until the VCO oscillation for the internal system becomes stable
after the following conditions
.
(Refer to Figure 2.)
1. The VDD becomes higher than the minimum operating voltage after the power is supplied.
2. The HOLD mode is released.
Seiko Epson
C-002RX
4.5 – 5.5V
Notes
The sample oscillation circuit characteristics may differ applications. For further assistance, please contact with oscillator
manufacturer with the following notes in your mind.
Since the oscillation frequency precision is affected by wiring capacity of the application board, etc., adjust the
oscillation frequency on the production board.
The above oscillation frequency and the operating supply voltage range are based on the operating temperature of -10
°
C
to +70
°
C. For the use with the temperature outside of the range herein, or in the applications requiring high reliability
such as car products, please consult with oscillator manufacturer.
When using the oscillator which is not shown in the sample oscillation circuit characteristics, please consult with Sanyo
sales personnel.
Since the oscillation circuit characteristics are affected by the noise or wiring capacity because the circuit is designed with low
gain in order to reduce the power dissipation, refer to the following notices.
The distance between the clock I/O terminal (XT1 terminal XT2 terminal) and external parts should be as short as
possible.
The capacitors’ VSS should be allocated close to the microcontroller’s GND terminal and be away from other GND.
The signal lines with rapid state changes or with large current should be allocated away from the oscillation circuit.
Figure 1 Recommended oscillation circuit.
C1
Rd
C2
X’tal
XT2
XT1
Rf