Ordering number: ENN6985
SANYO Electric Co.,Ltd. Semiconductor Company
TOKYO OFFICE Tokyo Bldg., 1-10, 1 Chome, Ueno, Taito-ku, TOKYO, 110-8534 JAPAN
Any and all SANYO products described or contained herein do not have specifications that can handle
applications that require extremely high levels of reliability, such as life-support systems, aircraft’s
control systems, or other applications whose failure can be reasonably expected to result in serious
physical and/or material damage. Consult with your SANYO representative nearest you before using
any SANYO products described or contained herein in such applications.
SANYO assumes no responsibility for equipment failures that result from using products at values that
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or other
parameters) listed in products specifications of any and all SANYO products described or contained
herein.
For General Audio Use
11 W 2-Channel BTL AF Power Amplifier
LA4636
Monolithic Linear IC
70102RM (II) No. 6985-1/3
Maximum Ratings
at Ta = 25
°
C
Parameter
Symbol
V
CC
max
I
o
peak
Pd max
Topr
Tstg
Conditions
Ratings
Unit
V
A
W
°
C
°
C
Maximum supply voltage
Maximum output current
Allowable power dissipation
Operating temperature
Storage temperature
No signal
Per channel
Infinite heat sink
24
2.5
25
–20 to +75
–40 to +150
Operating Conditions
at Ta = 25
°
C
Parameter
Symbol
V
CC
R
L
op
V
CC
op
Conditions
Ratings
12
4 to 8
5.5 to 20
5.5 to 17
5.5 to 13
Unit
V
V
V
V
Recommended supply voltage
Recommended load resistance
Allowable operating voltage range
R
L
= 8
R
L
= 6
R
L
= 4
*
1
Package Dimensions
unit: mm
3049B-SIP12H
[LA4636]
SANYO: SIP12H
Overview
The LA4636 is a BTL power IC that is pin-compatible
with the LA4635A and LA4635B single-end power ICs. It
represents a new concept in devices of this type by
allowing design editing based on common circuit board pin
compatibility for products of different power ranks. The
LA4636 also incorporates several protection circuits.
26.8
(20.0)
(
(
12
1
(
0.5
2.0
4.0
0.4
2.0
7
(2.4)
1.0
1
6
1
Set V
CC
, R
L
, and output level such that Pd max. is not exceeded for the size of heat sink used.
*1:Assuming two-channel output with an I
O
peak per channel exceeding 1.0 A. If the I
O
peak per channel is 1.0 A or
less, the allowable operating voltage range is 5.5 to 20 V (range not exceeding Pd max.) for all R
L
values.
Specifications