Current Transducer LA 205-S
For the electronic measurement of currents : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
Electrical data
I
PN
I
P
P max
R
M
Primary nominal r.m.s. current
Primary current, measuring range
Measuring overload
1)
Measuring resistance @
200
0 .. ± 300
600
A
A
A
T
A
= 70°C
R
M min
R
M max
R
M min
R
M max
0
68
0
33
5
95
5
50
T
A
= 85°C
with ± 12 V
@ ± 200 A
max
@ ± 300 A
max
@ ± 200 A
max
@ ± 300 A
max
0
0
5
5
66
30
93
49
with ± 15 V
I
SN
K
N
V
C
I
C
V
b
Secondary nominal r.m.s. current
Conversion ratio
Supply voltage (± 5 %)
Current consumption
R.m.s rated voltage
2)
, safe separation
100
1 : 2000
± 12 .. 15
20
(@ ± 15 V) +
I
S
mA
1625
3250
mA
V
V
V
basic isolation
Accuracy - Dynamic performance data
X
G
e
L
Overall accuracy @
I
PN
,
T
A
= 25°C
Linearity
± 0.8
< 0.1
%
%
Typ
Max
± 0.15
± 0.50
I
O
I
OM
I
OT
t
ra
t
di/dt
f
Offset current @
I
P
= 0,
T
= 25°C
Residual current
3)
@
I
P
= 0, after an overload of 3 x
I
PN
Thermal drift of
I
O
Reaction time @ 10 % of
I
Response time
4)
@ 90 % of
I
P max
di/dt
accurately followed
Frequency bandwidth (- 3 dB)
mA
mA
mA
- 10°C .. + 85°C
± 0.15 ± 0.30
< 500
< 1
> 100
DC .. 100
ns
μs
A/μs
kHz
General data
T
A
T
S
R
S
Ambient operating temperature
Ambient storage temperature
Secondary coil resistance @
- 10 .. + 85
- 40 .. + 90
35
37
110
EN 50178
°C
°C
T
A
= 70°C
T
A
= 85°C
m
Mass
Standards
5)
1)
3 mn/hour @
V
= ± 15 V,
R
= 5
2)
Pollution class nr 2. With a non insulated primary bar which fills the
through-hole
3)
The result of the coercive field of the magnetic circuit
4)
With a di/dt of 100 A/μs
5)
A list of corresponding tests is available
g
Notes :
Features
Closed loop (compensated) current
transducer using the Hall effect
Insulated plastic case recognized
according to UL 94-V0
Patent pending.
Advantages
Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
Current overload capability.
Applications
AC variable speed drives and servo
motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS)
Power supplies for welding
applications.
I
PN
=
200
A
980716/5