參數(shù)資料
型號: KSZ8842-16MQL
廠商: Micrel Inc
文件頁數(shù): 109/141頁
文件大?。?/td> 0K
描述: IC SWITCH 10/100 16BIT 128PQFP
標準包裝: 66
控制器類型: 以太網(wǎng)開關控制器
接口: PCI
電源電壓: 3.1 V ~ 3.5 V
工作溫度: 0°C ~ 70°C
安裝類型: 表面貼裝
封裝/外殼: 128-BFQFP
供應商設備封裝: 128-PQFP(14x20)
包裝: 管件
產(chǎn)品目錄頁面: 1081 (CN2011-ZH PDF)
配用: 576-1634-ND - BOARD EVALUATION KSZ8842-16MQL
其它名稱: 576-1478-5
Micrel, Inc.
KSZ8842-16/32 MQL/MVL/MVLI/MBL
October 2007
7
M9999-102207-1.9
Bank 48 Port 1 VID Control Register (0x04): P1VIDCR.......................................................................................................101
Bank 48 Port 1 Control Register 3 (0x06): P1CR3 ..............................................................................................................101
Bank 48 Port 1 Ingress Rate Control Register (0x08): P1IRCR...........................................................................................102
Bank 48 Port 1 Egress Rate Control Register (0x0A): P1ERCR .........................................................................................104
Bank 49 Port 1 PHY Special Control/Status, LinkMD (0x00): P1SCSLMD..........................................................................106
Bank 49 Port 1 Control Register 4 (0x02): P1CR4 ..............................................................................................................107
Bank 49 Port 1 Status Register (0x04): P1SR .....................................................................................................................108
Bank 50 Port 2 Control Register 1 (0x00): P2CR1 ..............................................................................................................109
Bank 50 Port 2 Control Register 2 (0x02): P2CR2 ..............................................................................................................109
Bank 50 Port 2 VID Control Register (0x04): P2VIDCR.......................................................................................................109
Bank 50 Port 2 Control Register 3 (0x06): P2CR3 ..............................................................................................................109
Bank 50 Port 2 Ingress Rate Control Register (0x08): P2IRCR...........................................................................................109
Bank 50 Port 2 Egress Rate Control Register (0x0A): P2ERCR .........................................................................................109
Bank 51 Port 2 PHY Special Control/Status, LinkMD (0x00): P2SCSLMD..........................................................................110
Bank 51 Port 2 Control Register 4 (0x02): P2CR4 ..............................................................................................................111
Bank 51 Port 2 Status Register (0x04): P2SR .....................................................................................................................113
Bank 52 Host Port Control Register 1 (0x00): P3CR1 .........................................................................................................114
Bank 52 Host Port Control Register 2 (0x02): P3CR2 .........................................................................................................114
Bank 52 Host Port VID Control Register (0x04): P3VIDCR .................................................................................................115
Bank 52 Host Port Control Register 3 (0x06): P3CR3 .........................................................................................................115
Bank 52 Host Port Ingress Rate Control Register (0x08): P3IRCR .....................................................................................115
Bank 52 Host Port Egress Rate Control Register (0x0A): P3ERCR ....................................................................................115
Banks 53 – 63: Reserved ....................................................................................................................................................115
MIB (Management Information Base) Counters................................................................................................ 116
Format of “All Ports Dropped Packet” MIB Counters ...........................................................................................................117
Additional MIB Information...................................................................................................................................................118
Static MAC Address Table .................................................................................................................................. 119
Static MAC Table Lookup Examples: ..................................................................................................................................119
Dynamic MAC Address Table ............................................................................................................................. 120
Dynamic MAC Address Lookup Example: ...........................................................................................................................120
VLAN Table ........................................................................................................................................................... 121
VLAN Table Lookup Examples: ...........................................................................................................................................121
Absolute Maximum Ratings
(1) ............................................................................................................................. 122
Operating Ratings
(1) ............................................................................................................................................. 122
Electrical Characteristics
(1) ................................................................................................................................. 123
Timing Specifications .......................................................................................................................................... 124
Asynchronous Timing without using Address Strobe (ADSN = 0) .......................................................................................124
Asynchronous Timing using Address Strobe (ADSN)..........................................................................................................125
Asynchronous Timing using DATACSN (KSZ8842-32MQL/MVL device only) ....................................................................126
Address Latching Timing for All Modes ...............................................................................................................................127
Synchronous Timing in Burst Write (VLBUSN = 1)..............................................................................................................128
Synchronous Timing in Burst Read (VLBUSN = 1)..............................................................................................................129
Synchronous Write Timing (VLBUSN = 0) ...........................................................................................................................130
Synchronous Read Timing (VLBUSN = 0)...........................................................................................................................131
EEPROM Timing .................................................................................................................................................................132
Auto Negotiation Timing ......................................................................................................................................................133
Reset Timing .......................................................................................................................................................................134
Selection of Isolation Transformers................................................................................................................... 135
Selection of Reference Crystal ........................................................................................................................... 135
Package Information ............................................................................................................................................ 136
Acronyms and Glossary...................................................................................................................................... 139
相關PDF資料
PDF描述
PIC16F631T-E/SS IC PIC MCU FLASH 1KX14 20SSOP
PIC16LF1906-E/MV MCU 14KB FLASH 512B RAM 28UQFN
KSZ8873MLL AM IC ETHERNET SWITCH 3PORT 64-LQFP
PIC16LF1825-E/ML MCU PIC 14KB FLASH 16QFN
PIC16F57-I/SP IC MCU FLASH 2KX12 28-DIP
相關代理商/技術參數(shù)
參數(shù)描述
KSZ8842-16MQL-EVAL 功能描述:以太網(wǎng)開發(fā)工具 KSZ8842-16MQL Evaluation Board RoHS:否 制造商:Micrel 產(chǎn)品:Evaluation Boards 類型:Ethernet Transceivers 工具用于評估:KSZ8873RLL 接口類型:RMII 工作電源電壓:
KSZ8842-16MVL 功能描述:以太網(wǎng) IC 2-Port Ethernet Switch/Repeater + Generic (8, 16-bit) bus interface(Lead Free) RoHS:否 制造商:Micrel 產(chǎn)品:Ethernet Switches 收發(fā)器數(shù)量:2 數(shù)據(jù)速率:10 Mb/s, 100 Mb/s 電源電壓-最大:1.25 V, 3.45 V 電源電壓-最小:1.15 V, 3.15 V 最大工作溫度:+ 85 C 封裝 / 箱體:QFN-64 封裝:Tray
KSZ8842-16MVL TR 功能描述:以太網(wǎng) IC 2-Port Ethernet Switch/Repeater + Generic (8, 16-bit) bus interface(Lead Free) RoHS:否 制造商:Micrel 產(chǎn)品:Ethernet Switches 收發(fā)器數(shù)量:2 數(shù)據(jù)速率:10 Mb/s, 100 Mb/s 電源電壓-最大:1.25 V, 3.45 V 電源電壓-最小:1.15 V, 3.15 V 最大工作溫度:+ 85 C 封裝 / 箱體:QFN-64 封裝:Tray
KSZ8842-16MVL-EVAL 功能描述:BOARD EVALUATION KSZ8842-16MVL RoHS:是 類別:編程器,開發(fā)系統(tǒng) >> 評估演示板和套件 系列:- 產(chǎn)品培訓模塊:Obsolescence Mitigation Program 標準包裝:1 系列:- 主要目的:電源管理,電池充電器 嵌入式:否 已用 IC / 零件:MAX8903A 主要屬性:1 芯鋰離子電池 次要屬性:狀態(tài) LED 已供物品:板
KSZ8842-16MVLI 功能描述:以太網(wǎng) IC 2-Port Ethernet Switch/Repeater + Generic (8, 16-bit) bus interface(Lead Free) RoHS:否 制造商:Micrel 產(chǎn)品:Ethernet Switches 收發(fā)器數(shù)量:2 數(shù)據(jù)速率:10 Mb/s, 100 Mb/s 電源電壓-最大:1.25 V, 3.45 V 電源電壓-最小:1.15 V, 3.15 V 最大工作溫度:+ 85 C 封裝 / 箱體:QFN-64 封裝:Tray