37
GENERAL
PURPOSE
FUSES
JLS CLASS J FUSES
600 VAC
I
Fast-Acting
I
1
600 Amperes
SPECIFICATIONS
Voltage ratings:
600 Volts AC
Interrupting ratings:
200,000 amperes rms symmetrical
Ampere range:
1
600 amperes
Approvals:
UL Listed Class J fuses per UL 248
(formerly UL 198C)
(File No. E81895)
CSA Certified HRCI-J (File No. LR29862)
Federal Specification No.WF1814 (QPL)
AMPERE RATINGS
1
3
6
10
15
20
Example part number (series & amperage): JLS 110
25
30
35
40
45
50
60
70
80
90
100
110
125
150
175
200
225
250
300
350
400
450
500
600
RECOMMENDED FUSE BLOCKS
LJ600 series
Refer to Fuse Block section of this catalog for additional infor-
mation.
LONGER EQUIPMENT LIFE
I
Current-limiting design reduces damage to equipment
caused by heating and magnetic effects of short-circuit
currents.
ECONOMICAL
I
Extremely current-limiting design often permits use of
readily available, less costly equipment.
I
Manufacturers of equipment containing dual voltage
devices can simplify manufacturing and reduce inventory
by standardizing on 600 volt JLS fuses and Class J fuse
blocks for all AC voltage ratings.
EASY TO USE
I
200,000 A.I.R. rating minimizes need for short-circuit
calculations.
NOTE:
Littelfuse JLS fuses are not time-delay fuses. For
applications where short-duration surges and spikes may
cause nuisance fuse opening, consider the use of Littelfuse
POWR-PRO
JTD series time-delay fuses.
JLS series fuses provide space-saving, fast-acting overload
and short-circuit protection for non-inductive loads.When
used for motors or other inductive loads, the ampere rating of
JLS series fuses must be increased to prevent nuisance
opening on inrush currents. In such applications, JLS fuses
may provide only short circuit protection. Consider using
Littelfuse POWR-PRO
JTD series time-delay fuses in such
circuits.
APPLICATIONS
General purpose circuits with little or no motor load.
Resistive loads, such as resistance electric heat.
Loads requiring fast-acting overload protection, such as
equipment containing solid-state devices.
SPACE SAVING
I
JLS fuse characteristics are similar to KLNR/KLSR fast-
acting Class RK1 fuses, but they are much smaller.
SAFETY
I
200,000 A.I.R.
Reliable interruption of all overcurrents up
to 200,000 amperes.
I
Extremely current limiting
Stops damaging short-circuit
current faster than any mechanical protective device.
I
Fast-acting
Provides fast-acting protection to equipment
such as variable speed drives, rectifiers and other equip-
ment containing surge-sensitive components.
相關PDF資料
PDF描述
JLS3 Fuse
JLS30 Fuse
JLS300 Fuse
JLS35 Fuse
JLS350 Fuse
相關代理商/技術參數(shù)
參數(shù)描述
JLS3 制造商:未知廠家 制造商全稱:未知廠家 功能描述:Fuse
JLS30 制造商:未知廠家 制造商全稱:未知廠家 功能描述:Fuse
JLS300 制造商:未知廠家 制造商全稱:未知廠家 功能描述:Fuse
JLS35 制造商:未知廠家 制造商全稱:未知廠家 功能描述:Fuse
JLS350 制造商:未知廠家 制造商全稱:未知廠家 功能描述:Fuse