Document Number: 83626
www.vishay.com
Revision 17-August-01
2–141
Characteristics TA=25°C
Symbol
Min.
Typ.
Max.
Unit
Condition
Emitter
Forward Voltage
VF
—
1.2
1.5
V
IF=20 mA
Reverse Voltage
VR
5.0
—
V
IR=10 A
Reverse Current
IR
——
10
A
VR=5.0 V
Detector
Forward Blocking
Voltage
VDRM
400
—
V
RGK=10 K
TA=100°C
Id=150 A
Reverse Blocking
Voltage
VDRRM
400
—
V
RGK=10 K
TA=100°C
Id=150 A
On-state Voltage
Vt
—
1.2
V
IT=100 mA
Holding Current
IH
—
500
ARGK=27 K
VFX=50 V
Gate Trigger
Voltage
VGT
—
0.6
1.0
V
VFX=100 V
RGK=27 K
RL=10 K
Forward Leakage
Current
ID
—
0.2
2.0
ARGK=27 K
VRX=400 V
IF=0, TA=25°C
Reverse Leakage
Current
IR
—
0.2
2.0
ARGK=27 K
VRX=400 V
IF=0, TA=25°C
Gate Trigger
Current
IGT
—20
50
AVFX=100 V
RGK=27 K,
RL=10 K
Package
Turn-0n Current
IFT
0.5
5.0
10.0
mA
VFX=100 V
RGK=27 K
Isolation
Capacitance
—
2
pF
f=1.0 MHz
.010 (.25)
typ.
.114 (2.90)
.130 (3.0)
.130 (3.30)
.150 (3.81)
.031 (0.80) min.
.300 (7.62)
typ.
.031 (0.80)
.035 (0.90)
.100 (2.54) typ.
.039
(1.00)
Min.
.018 (0.45)
.022 (0.55)
.048 (0.45)
.022 (0.55)
.248 (6.30)
.256 (6.50)
.335 (8.50)
.343 (8.70)
pin one ID
6
5
4
1
2
3
18
°
3
°–9°
.300–.347
(7.62–8.81)
4
°
typ.
1
2
3
6
5
4
Gate
Anode
Cathode
Anode
Cathode
NC
Dimensions in Inches (mm)
FEATURES
Turn On Current (IFT), 5.0 mA Typical
Gate Trigger Current (IGT), 20 A
Surge Anode Current, 1.0 Amp
Blocking Voltage, 400 V
Gate Trigger Voltage (VGT), 0.6 Volt
Isolation Voltage, 5300 VRMS
Solid State Reliability
Standard DIP Package
Underwriters Lab File #E52744
VDE Approval #0884
Available with Option 1
DESCRIPTION
The IL400 is an optically coupled SCR with a Gal-
lium Arsenide infrared emitter and a silicon photo
SCR sensor. Switching can be achieved while main-
taining a high degree of isolation between triggering
and load circuits. The IL400 can be used in SCR
triac and solid state relay applications where high
blocking voltages and low input current sensitivity
are required.
Maximum Ratings
Emitter
Peak Reverse Voltage ....................................... 6.0 V
Peak Forward Current
(100
s, 1% Duty Cycle)................................1.0 A
Continuous Forward Current ........................... 60 mA
Power Dissipation at 25
°C............................ 100 mW
Derate Linearly from 25
°C ........................ 1.3 mW/°C
Detector
Reverse Gate Voltage........................................ 6.0 V
Anode Voltage (DC or AC Peak) ...................... 400 V
Anode Current ............................................... 100 mA
Surge Anode Current (10 ms duration) ............. 1.0 A
Surge Gate Current (5.0 ms duration) ........... 200 mA
Power Dissipation, 25
°C ambient................. 200 mW
Derate Linearly from 25
°C ...................... 2.11 mW/°C
Package
Isolation Voltage .......................................5300 VRMS
Isolation Resistance
VIO=500 V, TA=25°C.............................min. 10
12
VIO=500 V, TA=100°C...........................min. 10
11
Total Package Dissipation ............................ 250 mW
Derate Linearly from 25
°C ...................... 2.63 mW/°C
Operating Temperature .................. –55
°C to +100°C
Storage Temperature ...................... –55
°C to +150°C
V
DE
IL400
Photo SCR Optocoupler