參數(shù)資料
型號: IL19006
廠商: INTEGRAL JOINT STOCK COMPANY
英文描述: THREE PHASE POWER/ENERGY METERING IC WITH INSTANTANEOUS PULSE OUTPUT
中文描述: 三相功率/電能計量IC瞬時脈沖輸出
文件頁數(shù): 8/12頁
文件大?。?/td> 290K
代理商: IL19006
ILA19006
Korzhenevskogo 12, Minsk, 220064, Republic of
Belarus
Fax: +375 (17) 278 28 22,
Phone: +375 (17) 278 07 11, 212 24 70, 212 24 61,
212 69 16
E-mail: office@bms.by
URL: www.bms.by
rated conditions. This facility provides ease of interface with applications which use the
same post divider with mechanical counter or unchanged microcontroller software for
different current rated kWh meters.
For example, a meter manufacturer may wish to build meters for 3 system configurations
with rated current loading of 80A
RMS
, 60A
RMS
and 40A
RMS
. The rated line voltage is
230V
RMS
.
FOUT1 Frequency
Consider the case where FOUT1 is the output of the energy counting block. For each
of the three rated conditions, the input current sensing resistors are chosen to ensure that
16μA
RMS
flows into the current sensing pins.
Case 1
I
L
= 80A
RMS
1 pulse on FOUT1 = (80*230*3)/1160 = 47.6Ws
Case 2
I
L
= 60A
RMS
1 pulse on FOUT1 = (60*230*3)/1160 = 35.7Ws
Case 3
I
L
= 40A
RMS
1 pulse on FOUT1 = (40*230*3)/1160 = 23.8Ws
The amount of energy represented by one pulse for each of the three cases is different.
In addition to changing the current sensing resistor network, the energy counting block
must also be altered.
FOUT2 Frequency
Now consider the advantage of the user selectable frequency available on FOUT2. Again
the input current sensing resistors must be chosen to ensure that 16μA RMS flows into the
current sensing pins.
Case 1
I
L
= 80A
RMS
,
PGM1 = 0
PGM0 = 0
1 pulse on FOUT2 = (80*230*3)/5.11 = 10.8kWs
Case 2
I
L
= 60A
RMS
,
PGM1 = 0
PGM0 = 1
1 pulse on FOUT2 = (60*230*3)/3.83 = 10.8kWs
Case 3
I
L
= 40A
RMS
,
PGM1 = 1
PGM0 = 0
1 pulse on FOUT2 = (40*230*3)/2.55 = 10.8kWs
The only changes which now have to be implemented to interface the device to different
rated systems are: change the current sense resistors; and select the required PGM0 and
PGM1.
No change to the post divider or micro-controller software is required if the FOUT2 pin is
used as described.
TYPICAL APPLICATION
In the Application Circuit (Figure 1), the components required for a three phase power
metering application are shown.
Terminated current sensors (current transformers) are connected to the current sensor
inputs of the IL19006 through current setting resistors (R
8
..R
13
).
相關(guān)PDF資料
PDF描述
IL202 Optocoupler DC-IN 1-CH Transistor With Base DC-OUT 6-Pin PDIP
IL203 Optocoupler DC-IN 1-CH Transistor With Base DC-OUT 6-Pin PDIP
IL203-X009T Optocoupler - Transistor Output, TRANSISTOR OUTPUT OPTOCOUPLER
IL202-X001 OPTOCOUPL DC-IN 1CH TRANS W/BASE DC-OUT 6PDIP - Bulk
IL256AT Optocoupler AC-IN 1-CH Transistor With Base DC-OUT 8-Pin SOIC N T/R
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
IL19-C20-H05-3150-200 制造商:Schaffner 功能描述:Power Cord with locking system, 250VAC, 50/60Hz, 16A 制造商:Schaffner 功能描述:Locking C19 IEC Cable 2M C20 IEC End
IL19-C20-SJT-3160-183 功能描述:6.0' (1.83m) Power Cord Black IEC 320-C20 To IEC 320-C19 SJT 制造商:schaffner emc inc. 系列:- 零件狀態(tài):有效 樣式:公頭插針(刀片)到插座(插槽) 第一連接器:IEC 320-C20 第二連接器:IEC 320-C19 導(dǎo)體數(shù):3 電線類型:SJT 線規(guī):- 屏蔽:- 長度:6.0'(1.83m) 認(rèn)證標(biāo)記:CSA,KEMA,PSE,RoHS,UR 認(rèn)證國家/地區(qū):加拿大,日本,荷蘭,英國,美國 顏色:黑 額定電壓:250V 額定電流:16A 工作溫度:-25°C ~ 70°C 特性:- 標(biāo)準(zhǔn)包裝:50
IL19-EU1-H05-3150-200 制造商:Schaffner 功能描述:Locking C19 IEC Cable 2M EU Plug
IL19-SE-H05-3150-200 制造商:Schaffner 功能描述:POWER CORD IEC C19/ FREE END 制造商:Schaffner 功能描述:POWER CORD, IEC C19/ FREE END, 2M, 16A 制造商:Schaffner 功能描述:Locking C19 IEC CableE 2M Stripped End
IL19-UK1-H05-3150-200 制造商:Schaffner 功能描述:Locking C19 IEC Cable 2M UK Plug