參數(shù)資料
型號: HY-3003
廠商: PerkinElmer Inc.
英文描述: Thyratrons
中文描述: 閘流管
文件頁數(shù): 2/6頁
文件大?。?/td> 49K
代理商: HY-3003
How a Thyratron works
The operation of the device can
be divided into three phases: trig-
gering and commutation (closure),
steady-state conduction, and
recovery (opening), each of which
is discussed below.
Triggering and Commutation
When a suitable positive trigger-
ing pulse of energy is applied to
the grid, a plasma forms in the
grid-cathode region from elec-
trons. This plasma passes through
the apertures of the grid structure
and causes electrical breakdown
in the high-voltage region
between the grid and the anode.
This begins the process of thyra-
tron switching (also called com-
mutation). The plasma that is
formed between the grid and the
anode diffuses back through the
grid into the grid-cathode space.
"Connection" of the plasma in the
anode-grid space with the plasma
in the cathode-grid space com-
pletes the commutation process.
The commutation process is sim-
ply modeled as shown in Figure 2.
The time interval between trigger
breakdown of the grid-cathode
region and complete closure of
the thyratron is called the anode
delay time. It is typically 100-200
nanoseconds for most tube types.
During commutation, a high volt-
age spike appears at the grid of
the thyratron. This spike happens
in the time it takes for the plasma
in the grid-anode space to "con-
nect" to the plasma in the grid-
cathode space. During this time,
the anode is momentarily "con-
nected" to the grid thereby caus-
ing the grid to assume a voltage
nearly that of the anode’s.
Although the grid spike voltage is
brief in duration, usually less than
100 nS, it can damage the grid
driver circuit unless measures
are taken to suppress the spike
before it enters the grid driver cir-
cuit. The location of the grid spike
suppression circuit is shown in
Figure 3, Grid Circuit.
Figure 4, Typical Grid Spike
Suppression Circuits, shows the
more common methods used to
protect the grid driver circuit. In
using any of these types of cir-
cuits, care must be exercised to
assure that the Grid Driver Circuit
pulse is not attenuated in an unac-
ceptable manner. The values for
the circuit components are
dependent on the characteristics
of the thyratron being driven, the
ANODE
CONTROL GRID (G2)
AUXILIARY GRID (G1)
CATHODE
Figure 1. Thyratron with auxiliary grid
(heater detail not shown)
e
e
1. Trigger pulse applied
to control grid.
2. Grid-cathode breakdown.
3. Electrons from grid-cathode
region create a dense plasma
in the grid-anode region. The
plasma front propagates to-
ward the cathode via break-
down of gas.
4. Closure
Figure 2. Thyratron commutation
Propagating
Plasma Front
相關(guān)PDF資料
PDF描述
HY-3004 Thyratrons
HY-3005 Thyratrons
HY-3025 Thyratrons
HY-3189 Thyratrons
HY-3192 Thyratrons
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
HY3003-2 制造商:DIGIMESS 功能描述:PSU BENCH 2 OUTPUT 0-30V 3A 制造商:DIGIMESS 功能描述:PSU, BENCH, 2 OUTPUT, 0-30V, 3A
HY3003-3 制造商:DIGIMESS 功能描述:PSU BENCH 2 X 0-30V 5V 3A 制造商:DIGIMESS 功能描述:PSU, BENCH, 2 X 0-30V, 5V, 3A
HY-3004 制造商:PERKINELMER 制造商全稱:PerkinElmer Optoelectronics 功能描述:Thyratrons
HY-3005 制造商:PERKINELMER 制造商全稱:PerkinElmer Optoelectronics 功能描述:Thyratrons
HY3010 制造商:DIGIMESS 功能描述:PSU BENCH 0-30V 10A 制造商:DIGIMESS 功能描述:PSU, BENCH, 0-30V, 10A