ASIA
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Fwai Fong, New Territories
Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
EUROPE
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44 (1384) 843-355
AMERICAS
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
153
www.astecpower.com
Watts
Input
voltage
1000
1250
1500
85-264 90-264 180-264
Module ID
HPS10
HPS12
HPS15
Code
Volts
Output Output Output
Amps
Amps
41.7
52.1
35.7
44.6
33.3
41.7
20.8
26.0
18.5
23.1
16.7
20.8
Amps
62.5
53.6
50.0
31.3
27.8
25.0
Q
R
S
W
X
Y
24.0
28.0
30.0
48.0
54.0
60.0
System
Code
Max. Size
(H x W x L)
Max. System
Power
Module
Distribution
Standard
Size
Unit
Weight
HPR3
5.22" x 19.0" x 14.0"
6000 W
(4 ea) HPS10/12/15 3U
16.4 lbs
Module
Code
Max. Size
(H x W x L)
Max. Module Max. Number
Power
Unit
Weight (lbs)
per Rack
HPS10
HPS12
HPS15
5.04" x 3.83" x 12.5"
5.04" x 3.83" x 12.5"
5.04" x 3.83" x 12.5"
1000 W
1250 W
1500 W
4
4
4
10.5
10.5
10.5
Watts
Input
voltage
Module Used
Rack ID
4000
5000
6000
85-264
HPS10
HPR3
100-264
HPS12
HPR3
180-264
HPS15
HPR3
Output
Amps
166.7
142.9
133.3
83.3
74.1
66.7
Output
Amps
208.3
178.6
166.7
104.2
92.6
83.3
Output
Amps
250.0
214.3
200.0
125.0
111.1
100.0
Code
Q
R
S
W
X
Y
Volts
24.0
28.0
30.0
48.0
54.0
60.0
Output Voltage
Q
= 24 V
R
= 28 V
S
= 30 V
W
= 48 V
X
= 54 V
Y
= 60 V
Z
=
Consult factory
I monitor
N =
None
A
= Current monitor
Power
10
= 1000 W
12
= 1250 W
15
= 1500 W
Redundancy
N
= None
R
= Or-ing diode
Standard Options
000
= No options
001
= 3.3 Standby
002
= Short circuit latch-off
004
= Enable “0”
008
= (Inhibit/enable), DC OK “1”
016
= Fan fail signal (optional)
032
= I
064
= AC line descriminator
128
= Temp OK “0”
256
= Module present “0”
Note: for combinations of options simply
add option codes together.
C interface
Auxiliary Fan
Voltage
N
= None
3
= 12 V @ 4 A
5
= 24 V @ 2 A
HPS
XXX
Size
3
= 3U
HPR
Standard Options
00
= No options
01
= computer option
Special Options
& Modifications
Contact Astec.
XXX
Special Options
& Modifications
Contact Astec.
Notes:
1. Specifications subject to change without notice
2. All dimentions are in inches (mm), toleance is ± .02”
3. Specifications are at factory settings
4. Warranty: 1 Yr
5. For combinations of options simply add option codes
together.
-
-
-
-
-
HPR3 Module Blank Panel:
Astec P/N 73-536-026
HPR3 Logic Blank Panel:
Astec P/N 73-536-027