HFE4003-02X/XXX
High Speed Fiber Optic LED
TEST CONDITIONS
TYP
ELECTRO-OPTICAL CHARACTERISTICS (-55C < T < 125C unless otherwise stated)
UNITS
MIN
PARAMETER
SYMBOL
MAX
I = 100 mA, 50/125 micron,
Fiber Coupled Power []
P
0.20 NA fiber, T = 25C []
W
10
15
HFE4003-023/XXX
dBm
-20
-18.2
W
20
25
HFE4003-024/XXX
dBm
-17.0
-16.0
I = 100 mA
Forward Voltage
V
1.70
2.00
I = 10 A
Reverse Voltage
Bá
V
1.0
5.0
I = 100 mA DC
Peak Wavelength
nm
850
I = 100 mA DC
Spectral Bandwidth
ê
nm
50
1 V Prebias, 100 mA peak
Response Time
ns
T = 25C, 10-90%
t
3
6
T = 25C, 90-10%
t
4
6
-55 < T < +125C, 10-90%
t
3
7
-55 < T < +125C, 90-10%
t
4
7
I = 100 mA DC, small
Analog Bandwidth
BWE
MHz
150
signal sinusoidal modulation
I = 100 mA
P Temperature Coefficient
êP/êT
dB/C
-0.01
DC
Series Resistance
r
í
4.0
V = 0 V, f = 1 MHz
Capacitance
C
pF
70
Heat sinked
Thermal Resistance
C/W
150
Notes
1. Dash numbers indicate power output. See ORDER GUIDE.
2. HFE4003-02X/XXX is tested using a 50/125 micron fiber cable. Actual coupled power values may vary due to mechanical alignment
procedures and/or receptacle and fiber tolerances.
ABSOLUTE MAXIMUM RATINGS
-65 to +150C
Storage temperature
-55 to +125C
Case operating temperature
260C, 10 s
Lead solder temperature
100 mA
Continuous forward current
(heat sinked)
1 V @ 10 A
Reverse voltage
Stresses greater than those listed under "Absolute Maximum
Ratings" may cause permanent damage to the device. This is a
stress rating only and functional operation of the device at these or
any other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods of time may affect
reliability.
TYPICAL COUPLED POWER (W/dBm) @ I=100 mA
@ I=100 mA
FIBER INTERFACE
Honeywell LEDs are designed to interface with
multimode fiber with sizes ranging from 50/125 to
200/230 microns. Honeywell performs final tests using
50/125 micron core fiber. All multimode fiber optic cables
between 50/125 and 200/230 should operate with similar
excellent performance. See table for typical powers.
-024
-023
N.A.
Index
Dia.
25/-16.0
15/-18.2
0.20
Graded
50/125
55/-12.6
33/-14.8
0.28
Graded
62.5/125
145/-8.4
91/-10.4
0.29
Graded
100/140
Honeywell reserves the right to make
changes in order to improve design and
supply the best products possible.
210
h