17
HFBR-14x4 Output Power Measured out of 1 Meter of Cable
HFBR-14x5 Output Power Measured out of 1 Meter of Cable
14x2/14x4 Dynamic Characteristics
Notes:
1. For I
FPK
> 100 mA, the time duration should not exceed 2 ns.
2. Typical data at T
A
= +25 °C.
3. Thermal resistance is measured with the transmitter coupled to a connector assembly and mounted on a printed circuit board.
4. D is measured at the plane of the fiber face and defines a diameter where the optical power density is within 10 dB of the maximum.
5. P
T
is measured with a large area detector at the end of 1 meter of mode stripped cable, with an ST precision ceramic ferrule (MILSTD- 83522/13)
for HFBR-1412/1414, and with an SMA 905 precision ceramic ferrule for HFBR-1402/1404.
6. When changing mW to dBm, the optical power is referenced to 1 mW (1000 mW). Optical Power P (dBm) = 10 log P (mW)/1000 mW.
7. Pre-bias is recommended if signal rate >10 MBd, see recommended drive circuit in Figure 11.
8. Pins 2, 6 and 7 are welded to the anode header connection to minimize the thermal resistance from junction to ambient. To further reduce the
thermal resistance, the anode trace should be made as large as is consistent with good RF circuit design.
9. Fiber NA is measured at the end of 2 meters of mode stripped fiber, using the far-field pattern. NA is defined as the sine of the half angle, determined
at 5% of the peak intensity point. When using other manufacturer’s fiber cable, results will vary due to differing NA values and specification
methods.
Parameter
Symbol
Min
Typ
2
Max
Units
Conditions
Reference
50/125 μm Fiber Cable
NA = 0.2
P
T50
-18.8
-19.8
-17.3
-18.9
-15.8
-13.8
-13.8
-12.8
-11.4
-10.8
dBm peak
T
A
= +25 °C, I
F
= 60mA dc
T
A
= +25 °C, I
F
= 100 mA dc
Notes 5, 6, 9
62.5/125 μm Fiber Cable
NA = 0.275
P
T62
-15.0
-16.0
-13.5
-15.1
-12.0
-10.0
-10.0
-9.0
-7.6
-7.0
dBm peak
T
A
= +25 °C, I
F
= 60mA dc
T
A
= +25 °C, I
F
= 100 mA dc
100/140 μm Fiber Cable
NA = 0.3
P
T100
-9.5
-10.5
-8.0
-9.6
-6.5
-4.5
-4.5
-3.5
-2.1
-1.5
dBm peak
T
A
= +25 °C, I
F
= 60mA dc
T
A
= +25 °C, I
F
= 100 mA dc
200 μm HCS Fiber Cable
NA - 0.37
P
T200
-5.2
-6.2
-3.7
-5.3
-3.7
-1.7
+0.8
+1.8
+3.2
+3.8
dBm peak
T
A
= +25 °C, I
F
= 60mA dc
T
A
= +25 °C, I
F
= 100 mA dc
Parameter
Symbol
Min
Typ
2
Max
Units
Conditions
Reference
62.5/125 μm Fiber Cable
NA = 0.275
P
T62
-11.0
-12.0
-10.0
-10.0
-8.0
-7.0
dBm peak
T
A
= +25 °C, I
F
= 60mA
Parameter
Symbol
Min
Typ
2
Max
Units
Conditions
Reference
Rise Time, Fall Time
(10% to 90%)
t
r
, t
f
4.0
6.5
nsec
No pre-
bias
I
F
= 60 mA
Figure 12
Note 7
Rise Time, Fall Time
(10% to 90%)
t
r
, t
f
3.0
nsec
I
F
= 10 to 100 mA
Note 7,
Figure 11
Pulse Width Distortion
PWD
0.5
nsec
Figure 11
All HFBR-14XX LED transmitters are classified as IEC 825-1 Accessible Emission Limit (AEL) Class 1 based upon the current proposed
draft scheduled to go in to effect on January 1, 1997. AEL Class 1 LED devices are considered eye safe. Contact your Agilent sales
representative for more information.
CAUTION: The small junction sizes inherent to the design of these components increase the components’ susceptibility to damage
from electrostatic discharge (ESD). It is advised that normal static precautions be taken in handling and assembly of these
components to prevent damage and/or degradation which may be induced by ESD.