208
HA-RELAYS
COST SAVING
SUBMINIATURE
PC BOARD RELAYS
HAE Amber Relays
mm
inch
14.0
.551
16.9
.665
26.3
1.035
26.5
1.043
14.2
.559
17.7
.697
FEATURES
Compact construction
Sensitive - very low operating power
Soldering flux inflow prevented by molded construction
Contact capacity - 3 A 250 V AC, 30 V DC
Simple mechanism for stable quality - only 9 pieceparts
Amber sealed types available
SPECIFICATIONS
HA1 Standard type
Contacts
Arrangement
Contact material
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Max. switching power
Max. switching voltage
Max. switching current
Mechanical
Coil
Minimum operating power
Nominal operating power
Characteristics
Maximum operating speed
Initial insulation resistance*
(at 25
°
C, 50% R.H.)
Initial
breakdown
voltage*
Operate time*
(at 20
°
C)
Release time (without diode)*
(at nominal voltage)(at 20
HA1E Amber sealed type
Contacts
Arrangement
Contact material
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Max. switching power
Max. switching voltage
Max. switching current
Mechanical
Coil
Minimum operating power
Nominal operating power
Characteristics
Maximum operating speed
Initial insulation resistance*
(at 25
°
C, 50% R.H.)
Initial
breakdown
voltage*
Operate time*
(at 20
°
C)
Release time (without diode)*
(at nominal voltage)(at 20
1 Form C
Silver-nickel
50 m
Rating
(resistive
load)
750 VA, 90 W
250 V AC, 30 V DC
3 A
10
10
5
×
10
Expected
life (min.
operations)
7
Electrical
(resistive)
3 A 250 V AC
3 A 30 V DC
5
5
(AC) 0.58 VA, (DC) 230 mW
(AC) 0.9 VA, (DC) 360 mW
20 cpm
1
Min. 100 M
at 500 V DC
2
Between open contacts
750 Vrms for 1 min.
Between contacts and coil
1,500 Vrms for 1 min.
3
(at nominal voltage)
Approx. 6 ms (AC),
Approx. 5 ms (DC)
Approx. 6 ms (AC),
Approx. 3 ms (DC)
Max. (AC) 60
with nominal coil voltage and
at 3A switching current
98 m/s
980 m/s
10 to 55Hz
at double amplitude of 1mm
10 to 55Hz
at switching of 2mm
°
C to +50
–40
°
F to +122
3
°
C)
Temperature rise (at 20
°
C)
°
C, (DC) 40
°
C
Shock resistance
Functional
Destructive
2
{10G}
{100G}
2
Vibration resistance
Functional
Destructive
Conditions for operation,
transport and storage*
(Not freezing and con-
densing at low tempera-
ture)
Unit weight
Remarks
* Specifications will vary with foreign standards certification ratings.
*
Measurement at same location as "Intial breakdown voltage" section
*
Detection current: 10 mA
4
Ambient
temp.
–40
°
C
°
F
Humidity
5 to 85%R.H.
Approx. 15 g
.53 oz
1 Form C
Gold-clad over silver-nickel
50 m
Rating
(resistive
load)
500 VA, 90 W
250 V AC, 30 V DC
2 A AC, 3A DC
10
10
2
×
10
Expected
life (min.
operations)
7
Electrical
(resistive)
2 A 250 V AC
3 A 30 V DC
5
5
(AC) 0.58 VA, (DC) 230 mW
(AC) 0.9 VA, (DC) 360 mW
20 cpm
1
Min. 100 M
at 500 V DC
2
Between open contacts
750 Vrms for 1 min.
Between contacts and coil
1,500 Vrms for 1 min.
3
(at nominal voltage)
Approx. 6 ms (AC),
Approx. 5 ms (DC)
Approx. 6 ms (AC),
Approx. 3 ms (DC)
Max. (AC) 60
with nominal coil voltage and
at 3A switching current
98 m/s
980 m/s
10 to 55Hz
at double amplitude of 1mm
10 to 55Hz
at double amplitude of 2mm
°
C to +50
–40
°
F to +122
3
°
C)
Temperature rise (at 50
°
C)
°
C, (DC) 40
°
C
Shock resistance
Functional
Destructive
2
{10G}
{100G}
2
Vibration resistance
Functional
Destructive
Conditions for operation,
transport and storage*
(Not freezing and con-
densing at low tempera-
ture)
Unit weight
4
Ambient
temp.
–40
°
C
°
F
Humidity
5 to 85%R.H.
Approx. 15 g
.53 oz
1
2
*
*
3
Excluding contact bounce time
Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 61).
4