Multifunction Preset Counter
H7CX (Counter Function)
Note: 1.
The full scale (FS) for H7CX 4-digit models is 9999.
2.
When the present value reaches 999999, it returns to 0.
3.
Counting cannot be performed during reset/reset 1 input.
4.
If reset/reset 1 is input while one-shot output is ON, one-shot output turns OFF.
5.
If there is power failure while output is ON, output will turn ON again when the power supply has recovered. For one-shot output, output
will turn ON again for the duration of the output time setting once the power supply has recovered.
6.
Do not use the counter function in applications where the count may be completed (again) while one-shot output is ON.
Input mode
DOWN
Operation after
count completion
UP
UP/DOWN A, B, C
Output
mode
setting
K-1
The present value dis-
play continues to in-
crease/decrease.
OUT1 self-holding
output turns OFF after
the OUT2 one-shot
output time.The
OUT1 one-shot out-
put time is indepen-
dent of OUT2.
P
The present value dis-
play does not change
during the one-shot
output time period,
but the actual count
returns to the reset
start status.
The outputs return to
the one-shot start
state and repeat one-
shot operation.
OUT1 self-holding
output turns OFF after
the OUT2 one-shot
output time. The
OUT1 one-shot out-
put time is indepen-
dent of OUT2.
The present value
continues to increase/
decrease for the one-
shot output time, but
returns to the reset
start status after the
one-shot output time
has elapsed.
The outputs repeat
one-shot operation.
OUT1 self-holding
output turns OFF after
the OUT2 one-shot
output time. The
OUT1 one-shot out-
put time is indepen-
dent of OUT2.
The present value dis-
play and OUT1 self-
holding output is held
until reset/reset 1 is
input. OUT1 and
OUT2 are indepen-
dent.
Q
A
9Set
value 2
Set
value 1
0
OUT1
OUT2
Reset/
reset 1
999999
Set
value 2
Set
value 1
0
OUT1
OUT2
Reset/
reset 1
999999
Set
value 2
Set
value 1
0
OUT1
OUT2
Reset/
reset 1
999999
Set
value 2
Set
value 1
0
OUT1
OUT2
Reset/
reset 1