GENNUM CORPORATION
521 - 96 - 07
2 of 10
G
ABSOLUTE MAXIMUM RATINGS
PARAMETER
VALUE
Supply Voltage (V
S
= V
CC
-V
EE
)
5.5V
Input Voltage Range (any input)
V
EE
<V
IN
<V
CC
DC Input Current (any one input)
5mA
Power Dissipation (V
CC
= 5.25V)
1200mW
θ
j-a
42.5
°
C/W
θ
j-c
6.4
°
C/W
Maximum Die Temperature
125
°
C
Operating Temperature Range
0
°
C
≤
T
A
≤
70
°
C
Storage Temperature Range
-65
°
C
≤
T
S
≤
150
°
C
Lead Temperature (soldering, 10 sec)
260
°
C
DC ELECTRICAL CHARACTERISTICS
V
CC
= 5V, V
EE
= 0V, T
A
= 0
°
–
70
°
C unless otherwise specified.
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
MAX
UNITS
NOTES
TEST
LEVEL
Positive Supply Voltage
V
CC
Operating Range
4.75
5.00
5.25
V
3
Power (System Power)
P
V
CC
= 5.0V, T = 25
°
C (4 outputs)
-
675
-
mW
5
Supply Current
Ι
CC
V
CC
= 5.25V (4 outputs)
-
-
180
mA
1
V
CC
= 5.0V, T = 25
°
C (4 outputs)
-
135
-
3
V
CC
= 5.25V (2 outputs)
-
-
160
1
V
CC
= 5.0V, T = 25
°
C (2 outputs)
-
110
-
7
Data & Clock Inputs
(PD[9:0] PCLKIN)
SYNC DIS
V
IH
Logic Input High (wrt V
EE
)
2.4
-
-
V
3
V
IL
Logic Input Low (wrt V
EE
)
-
-
0.8
V
Ι
L
Input Current
-
-
8.0
μA
Logic Input Levels
(Auto/Man, SS[2:0]
Bypass, RESET)
V
IH
Logic Input High (wrt to V
EE
)
2.4
-
-
V
3
V
IL
Logic Input Low (wrt to V
EE
)
-
-
0.8
V
Ι
L
Input Current
-
-
5.0
μA
Lock Detect Output
V
OL
Sinking 500μA
-
-
0.4
V
1
TEST LEVELS
1. Production test at room temperature and nominal supply voltage with guardbands for supply and temperature ranges.
2. Production test at room temperature and nominal supply voltage with guardbands for supply and temperature ranges using correlated
test.
3. Production test at room temperature and nominal supply voltage.
4. QA sample test.
5. Calculated result based on Level 1,2, or 3.
6. Not tested. Guaranteed by design simulations.
7. Not tested. Based on characterization of nominal parts.
8. Not tested. Based on existing design/characterization data of similar product.