2000 TELEDYNE RELAYS
800-284-7007 www.teledynerelays.com
GD 1
6A, 230/240VAC, 300VDC
SINGLE THROW FOUR POLE
ELECTRICAL SPECIFICATIONS
GENERAL SPECIFICATIONS
Parameter
Min
Typ
Max Units
Operate Time (See Note 1)
17
msec
Release Time (See Note 1)
7
msec
Switching Frequency
5
Hz
Shock (11 msec, See Note 3)
10
g
Vibration (10-200 Hz, See Note 3)
5
g
Electrical Life
10
5
Cycles
Mechanical Life
10
7
Cycles
Ambient Temperature
-25
80
o
C
CONTACT SPECIFICATIONS
Maximum Load Current
1 Contacts
6
A
2 Contacts
4.2
A
3 Contacts
3.5
A
Maximum Switching Voltage
230/240 Vac
300
Vdc
Maximum Load Capacity (Resistive)
1500/30VA/W
Maximum Switching Capacity
AC15-230/240V
4
Arms
(Inductive)
DC13-24V
2
Adc
Contact Resistance (See Note 2)
100 mOhm
Dielectric Test Voltage (O=III, P=2)
Coil to Contact
2500
Contact to Contact
2000
Vac
Series GD
Force guided relay rated for 6A, 230/240 Vac, 300 Vdc Available
in 4 pole configuration. Polarized DC Drive. See Table 1 for part
numbers.
FEATURES:
Force Guided Contacts per EN50205:
Consists of at least one NO and one NC
contact mechanically linked. This allows
the contact‘s behavior to be pre-
determined and the user the ability to
monitor the contact.The mechanism
provides true status.
Dielectric designed for 3-phase systems.
Contacts are physically linked making it
impossible for a NO and NC to be closed
simultaneously.
Internal creepage distances and
clearances are designed for Overvoltage
Category III and Degree of Pollution 2 per
IEC 60664.
Wide range of Contact configurations and
Coil Voltages.
APPROVALS:
CUL: Approved
TüV / VDE: Pending
ACCESSORIES:Contact Factory
Current regulator unit DIL housing
Current regulator unit SO.8 housing
Removing tool
Socket with soldering pins for PCB mounting
Socket for conventional mounting.
New Series GD