G6Y
G6Y
CONTACT DATA
Load
Rated load
Resistive load (p.f. = 1)
0.01 A at 30 VAC
0.01 A at 30 VDC
900 MHz, 1 W (See Note.)
Au clad
Cu alloy
0.5 A
30 VAC
30 VDC
Contact material
Max. carry current
Max. operating voltage
Max. operating current
Max. switching capacity
0.5 A
AC10 VA
DC10 W
Min. permissible load
10 mA at 10 mVDC
Note: This value is for a load with VSWR
1.2.
HIGH-FREQUENCY CHARACTERISTICS
Item
Isolation
Insertion loss
VSWR
250 MHz
80 dB min.
0.5 dB max.
1.5 max.
900 MHz
65 dB min.
0.5 dB max.
1.5 max.
2.5 GHz
30 dB min.
consult factory
Max. carry power
Max. operating power
10 W
10 W (See Note 2.)
Note: 1.
The impedance of the measuring system is 50
. The table above shows preliminary values.
This value is for a load with VSWR
1.2.
2.
CHARACTERISTICS
Contact resistance (See Note 2.)
Operating time
Release time
Insulation resistance
Dielectric strength
100 m
max.
10 ms max. (approx. 5 ms)
5 ms max. (approx. 1 ms)
100 M
min. (at 500 VDC)
1,000 VAC, 50/60 Hz for 1 min between coil and contacts
500 VAC, 50/60 Hz for 1 min between contacts of same polarity
500 VAC, 50/60 Hz for 1 min between coil and ground and between contacts
and ground
Destruction: 10 Hz to 55 Hz, 1.5 mm double amplitude
Malfunction: 10 Hz to 55 Hz, 1.5 mm double amplitude
Destruction: 1,000 m/s
2
(approx. 100G)
Malfunction: 1,000 m/s
2
(approx. 100G)
Mechanical: 1,000,000 operations min. (at 1,800 operations/hr.)
Electrical: 300,000 operations min. (under rated load at 1,800 operations/hr.)
--40
°
C to 70
°
C (--40
°
F to 158
°
F) with no icing
--40
°
C to 70
°
C (--40
°
F to 158
°
F) with no icing
35 to 85%
35 to 85%
Approx. 5 g
Vibration resistance
Shock resistance
Life expectancy
Ambient temperature
b e
Operating
Storage
Operating
Storage
e a u e
Ambient humidity
Weight
Note: 1.
The table above shows preliminary values at room temperature unless otherwise specified.
Measurement Conditions: 5 VDC, 100 mA, voltage drop method.
2.